基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Objective: The purpose of this study was to determine how the slice thickness reconstruction influences quantitative perfusion CT parameters. Materials and Methods: Eighteen patients with cancer (15 non-small-cell lung cancer, 2 rectal cancer and 1 renal cancer) were examined prospectively with multidetector row CT. A 90-second perfusion study was performed after intravenous bolus injection of contrast material. Blood flow, blood volume, mean transit time and permeability-surface area product were determined at three different slice thickness reconstruction (1.25, 2.5 and 5 mms) both in tumors and in paraspinal muscle. Mean values, limits of agreement between measurements and within-subject coefficient of correlation were obtained for these thicknesses. Results: Mean ± standard deviation BF, BV, MTT and PS in lesions were 118.7 ± 117.9 mL/min/100g tissue, 8.2 ± 8.2 mL/100g tissue, 7.5 ± 5.4 seconds and 10.3 ± 7.2 mL/min/100g tissue respectively at1.25 mmslice thickness;116.1 ± 115.7 mL/min/100g tissue, 7.8 ± 8.7 mL/100g tissue, 7 ± 4.5 seconds and 10.4 ± 7.5 mL/min/100g tissue at 2.5 mms;and 119.6 ± 115.7 mL/min/100g tissue, 7.8 ± 8.8 mL/100g tissue, 5.4 ± 3.4 seconds and 9.6 ± 7.5 mL/min/100g tissue at 5 mms. Differences between means for different slice thickness where relatively small in all parameters (<15%) except in MTT where difference was up to 37%. 95% limits of agreement were worse when comparing more different slice thicknesses (e.g. 1.25 vs 5 mms) than when comparing more close slice thicknesses (1.25 vs 2.5 mms or 2.5 vs 5 mms). Conclusions: There is a significant variability in perfusion parameter measurements at different slice thickness reconstruction, particularly in MTT. The more close together the slice thicknesses were, the smaller was the variability.
推荐文章
基于GPU实现SlideShow中的effect和transition
图像处理器
Direct3D
SlideShow
固定功能流水线
可编程流水线
高级渲染语言
顶点渲染
像素渲染
Elemental characteristics and paleoenvironment reconstruction: a case study of the Triassic lacustri
Trace elements
Occurrence mode
Paleoenvironment
Zhangjiatan oil shale
Yanchang Formation
Ordos Basin
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Effect of Slice Thickness Reconstruction on Quantitative Vascular Parameters in Perfusion CT
来源期刊 放射学期刊(英文) 学科 医学
关键词 TOMOGRAPHY NEOPLASMS BLOOD Supply DIAGNOSTIC Imaging
年,卷(期) fsxqkyw_2014,(1) 所属期刊栏目
研究方向 页码范围 53-59
页数 7页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2014(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
TOMOGRAPHY
NEOPLASMS
BLOOD
Supply
DIAGNOSTIC
Imaging
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
放射学期刊(英文)
季刊
2164-3024
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
256
总下载数(次)
0
论文1v1指导