Purpose: The accuracy of Goldmann applanation tonometry (GAT) has been shown to depend on several biomechanical properties of the cornea. Newer tonometry devices (e.g., the Dynamic Contour Tonometer PASCAL? [DCT] and the Tono-Pen? XL [TP]) have been designed to accurately measure intraocular pressure (IOP) independent of corneal thickness (CCT) and pathology. This study investigates the influence of corneal pathologies on the accuracy of these IOP measuring devices, and compares this accuracy to that of direct intracameral IOP measurement. Methods: 8 eyes of 8 patients suffering from corneal pathologies scheduled for penetrating keratoplasty, and 10 eyes of 10 patients scheduled for cataract surgery (control group) were examined. Before surgery, the anterior chamber was cannulated at the temporal corneal limbus. In a closed system, the intraocular pressure (IOP) was directly set to 10, 20, and 30 mmHg with a manometric water column. Intraocular pressure measurements taken by GAT, DCT, and TP were compared to intracameral measurements obtained by a precision reference pressure sensor. Results: Control group: All three methods showed good agreement with the intracameral readings (mean deviation of all three devices, -0.9 mmHg). Group with corneal pathologies: The TP yielded the most exact IOP values in the group with corneal pathologies when taking all diagnoses into account. The mean deviations from the intracameral IOP measurements were -0.9 mmHg ± 3.2 mmHg (mean ± SD) for TP, -2.9 mmHg ± 3.3 mmHg for GAT, and -5.0 mmHg ± 7.9 mmHg for DCT. For bullous keratopathy, the most exact IOP readings were obtained by the TP (mean deviation -0.2 mmHg ± 3.5 mmHg). The TP and GAT devices underestimated IOP in the patients with Fuchs’ endothelial dystrophy;all 3 devices underestimated adjusted IOP after keratoplasty. DCT showed the greatest deviations from adjusted IOP in the case of non-herpetic scars. In the control group, none of the devices showed a statistically relevant dependency on CCT. Nevertheless, in the gro
推荐文章
Tono-Pen眼压计与Goldmann眼压计的临床比较
眼压
Tono-Pen眼压计
Goldmann眼压计
Tono-pen眼压计的可重复性和准确性研究
Tono-pen 眼压计
Goldmann 眼压计
可重复性
准确性
Tono-pen眼压计与Goldmann眼压计对穿透性小梁切除术后患者眼压测量的比较
穿透性小梁切除术
眼压
Tono-pen眼压计
Goldmann眼压计
4种眼压计对近视患者准分子激光原位角膜磨镶术后测压的应用价值比较——附53例报告
近视
准分子激光原位角膜磨镶术
中央角膜厚度
压平眼压计
动态轮廓眼压计
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Dynamic Contour Tonometry, Tono-Pen XL<sup>®</sup>, and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure (IOP) Measurements in Patients with Corneal Pathologies
来源期刊 眼科学期刊(英文) 学科 医学
关键词 KERATOPLASTY IOP Measurement GOLDMANN Applanation TONOMETRY Dynamic Contour TONOMETRY Tono-Pen XL?
年,卷(期) 2014,(2) 所属期刊栏目
研究方向 页码范围 46-55
页数 10页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2014(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
KERATOPLASTY
IOP
Measurement
GOLDMANN
Applanation
TONOMETRY
Dynamic
Contour
TONOMETRY
Tono-Pen
XL?
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
眼科学期刊(英文)
季刊
2165-7408
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
241
总下载数(次)
0
总被引数(次)
0
论文1v1指导