基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
OBJECTIVE: The primary objective of the S-CORE registry was to assess the safety and efficacy of the Supralimus-Core? sirolimus-eluting stent deployment for the treatment of coronary artery disease and event-free survival of patients treated with this coronary stent. METHODS: S-CORE Registry is an observational, single-arm, non-randomized, post-marketing surveillance multicenter registry in which 562 patients undergoing single or multi-vessel percutaneous coronary intervention were enrolled. The pre-specified primary outcome was the rate of major adverse cardiac events (MACE), defined as the composite of cardiac death, myocardial infarction (MI), target lesion revascularisation (TLR) and target vessel revascularisation (TVR) at 12-month post-procedure. Stent thrombosis (ST) served as the safety endpoint. RESULTS: A total of 640 lesions were treated in 562 enrolled patients (mean age 57.4 ± 10.7 years) with average stent length of 25.0 ± 9.0 mm. Stent delivery was successful in 99% cases. A total of 554 (98.6%) patients have been followed up to 12 months. The incidence of MACE at 30 days and 6 months was 7 (1.2%) and 12 (2.1%) respectively. The composite rate of MACE at a 12-month clinical follow-up was 19 (3.4%), consisting of 12 (2.1%) cardiac deaths, 0 (0%) MI, 6 (1.1%) TLR and 1 (0.2%) TVR. The long-term follow-up of this registry is going on to confirm safety and efficacy profiles. CONCLUSIONS: This multicenter registry demonstrated satisfactory safety and efficacy profiles, as evidenced by low rates of major adverse cardiac events up to 12 months, for the cobalt-chromium biodegradable polymer-based sirolimus-eluting Supralimus-Core? stent in a “real-world” setting.
推荐文章
直接PTCA+Stent治疗急性心肌梗死对QTc离散度的影响
心电描记术
心肌梗塞
血管成形术,经腔,经皮冠状动脉
基于World Wide Web的课件设计方法
课件
WWW
教学
多媒体
Real与Media流媒体技术比较
Real
Media
流媒体
比较
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Clinical Performance of the Cobalt-Chromium Biodegradable Polymer Coated Sirolimus-Eluting Stent in an Unselected Real-World Population
来源期刊 临床医学国际期刊(英文) 学科 医学
关键词 CORONARY ARTERY Disease BIODEGRADABLE Polymer Sirolimus-Eluting STENT
年,卷(期) 2014,(5) 所属期刊栏目
研究方向 页码范围 206-215
页数 10页 分类号 R5
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2014(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
CORONARY
ARTERY
Disease
BIODEGRADABLE
Polymer
Sirolimus-Eluting
STENT
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
临床医学国际期刊(英文)
月刊
2158-284X
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
962
总下载数(次)
0
  • 期刊分类
  • 期刊(年)
  • 期刊(期)
  • 期刊推荐
论文1v1指导