基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM:To evaluate differences in flap thickness resulting from use of an Alcon Wavelight FS200 femtosecond laser and a MORIA SBK microkeratome when making a110-μm-thick corneal flap and to identify the potential factors that affect corneal flap thickness.METHODS:A prospective case study was performed on 120 eyes of 60 patients who were divided into two groups for LASIK,each group consisting of 60 eyes(30patients).The corneal flaps were created using an Alcon Wavelight FS200 femtosecond laser or a MORIA SBK microkeratome.The central corneal flap thickness was calculated by subtraction pachymetry.Age,central corneal thickness(CCT),spherical equivalent refraction,mean keratometry,and corneal diameter were recorded preoperatively for analysis.RESULTS:Cutting of all flaps was easily performed without intraoperative complications.In the Alcon Wavelight FS200 femtosecond laser group,the mean right and left corneal flap thicknesses were 114.0±6.6μm(range:98-126)and 111.4±7.6μm(range:98-122),respectively.The difference(2.6±9.1μm)in the corneal flap thickness between the right and left eyes was not significant(t=1.59,P=0.12).Stepwise regression analysis indicated that the resulting corneal flap thickness was unrelated to the patient’s age,preoperative CCT,spherical equivalent refraction,mean keratometry,or corneal diameter.In the MORIA SBK microkeratome group,the mean right and left corneal flap thicknesses were 110.6±7.4μm(range:97-125μm)and 108.2±6.1μm(range:78-123μm),respectively.The difference in the corneal flap thickness between the right and left eyes(2.4±6.5μm)was not significant(t=2.039,P=0.0506).Thecorneal flap thickness was positively correlated with the preoperative CCT through stepwise regression analysis(r=0.297,P=0.021).The corneal flap thickness was not related to age,spherical equivalent refraction,mean keratometry,or corneal diameter.The corneal flap thickness was estimated using the following equation:Tflap=67.77+0.076 CCT(F=5.63,P=0.021).CONCLUSION:Both the Alcon Wavelight FS200femtoseco
推荐文章
FS-LASIK手术和SBK手术对视网膜厚度影响的比较
飞秒激光
准分子激光原位角膜磨镶术
视网膜神经纤维层厚度
相干光断层扫描
飞秒激光制瓣和SBK角膜板层刀制瓣在LASIK手术中的比较
飞秒激光制瓣
SBK角膜板层刀制瓣
LASIK手术
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 用 FS200 femtosecond 激光和 moria SBK microkeratome 的角膜的拍动厚度的比较
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 corneal flap thickness FEMTOSECOND LASER LASER in situ KERATOMILEUSIS MICROKERATOME
年,卷(期) 2014,(2) 所属期刊栏目
研究方向 页码范围 273-277
页数 5页 分类号 R772.2
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (42)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2014(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
corneal
flap
thickness
FEMTOSECOND
LASER
LASER
in
situ
KERATOMILEUSIS
MICROKERATOME
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
论文1v1指导