基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM: To determine the diagnostic accuracy and radiation dose of conventional radiography and multidetector computed tomography(MDCT) in suspected scaphoid fractures.METHODS: One hundred twenty-four consecutive patients were enrolled in our study who had suffered from a wrist trauma and showed typical clinical symptoms suspicious of an acute scaphoid fracture. All patients had initially undergone conventional radiography. Subsequent MDCT was performed within 10 d because of persisting clinical symptoms. Using the MDCT data as the reference standard, a fourfold table was used to classify the test results. The effective dose and impaired energy were assessed in order to compare the radiation burden of the two techniques. The Wilcoxon test was performed to compare the two diagnostic modalities.RESULTS: Conventional radiography showed 34 acute fractures of the scaphoid in 124 patients(42.2%). Subsequent MDCT revealed a total of 42 scaphoid fractures. The sensitivity of conventional radiography for scaphoid fracture detection was 42.8% and its specificity was 80% resulting in an overall accuracy of 59.6%. Conventional radiography was significantly inferior to MDCT(P 【 0.01) concerning scaphoidfracture detection. The mean effective dose of MDCT was 0.1 m Sv compared to 0.002 m Sv of conventional radiography.CONCLUSION: Conventional radiography is insufficient for accurate scaphoid fracture detection. Regarding the almost negligible effective dose, MDCT should serve as the first imaging modality in wrist trauma.
推荐文章
Using Geomechanical Method to Predict Tectonic Fractures in Low-Permeability Sandstone Reservoirs
Low-permeability sandstone reservoir
Fracture parameters
Geomechanical method
MDCT对胃癌术前分期的应用价值
胃癌
多层螺旋CT
术前分期
新辅助化疗
MDCT冠状重组诊断阑尾炎的价值
阑尾炎
多排螺旋CT
冠状重组
基于小区域增长的MDCT图像分割
图像分割
小区域增长
MDCT图像
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Comparison of conventional radiography and MDCT in suspected scaphoid fractures
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 MUSCULOSKELETAL imaging SCAPHOID fracture MULTIDETECTOR computed tomography Biplane radiography Emergency RADIOLOGY Diagnostic accuracy WRIST trauma Dose calculation
年,卷(期) 2015,(1) 所属期刊栏目
研究方向 页码范围 22-27
页数 6页 分类号 R683
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2015(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
MUSCULOSKELETAL
imaging
SCAPHOID
fracture
MULTIDETECTOR
computed
tomography
Biplane
radiography
Emergency
RADIOLOGY
Diagnostic
accuracy
WRIST
trauma
Dose
calculation
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导