AIM: To characterize the effects of iodinated contrast material(ICM) on magnetic resonance imaging(MRI) comparing different sequences and magnetic fields, with emphasis to similarities/differences with well-known signal characteristics of hemorrhage in the brain. METHODS: Aliquots of iopamidol and iodixanol mixed with normal saline were scanned at 1.5T and 3T. Signal intensity(SI) was measured using similar spin-echo(SE)-T1, SE-T2, gradient-echo(GRE) and fluid-attenuationinversion-recovery(FLAIR) sequences at both magnets. Contrast to noise ratio(CNR)(SI contrast-SI saline/SD noise) for each aliquot were calculated and Kruskall-wallis test and graphic analysis was used to compare different pulse sequences and ICMs. RESULTS: Both ICM showed increased SI on SE-T1 and decreased SI on SE-T2, GRE and FLAIR at both 1.5T and 3T, as the concentration was increased. By CNR measurements, SE-T2 had the greatest conspicuity at 3T with undiluted iopamidol(92.6 ± 0.3, P < 0.00) followed by iodixanol(77.5 ± 0.9, P < 0.00) as compared with other sequences(CNR range: 15-40). While SE-T2 had greatest conspicuity at 1.5T with iopamidol(49.3 ± 1, P < 0.01), SE-T1 showed similar or slightly better conspicuity(20.8 ± 4) than SE-T2 with iodixanol(23 ± 1.7). In all cases, hypo-intensity on GRE was less conspicuous than on SE-T2.CONCLUSION: Iodixanol and iopamidol shorten T1 and T2 relaxation times at both 1.5T and 3T. Hypo-intensity due to shortened T2 relaxation time is significantly more conspicuous than signal changes on T1-WI, FLAIR or GRE. Variations in signal conspicuity according to pulse sequence and to type of ICM are exaggerated at 3T. We postulate T2 hypointensity with less GRE conspicuity differentiates ICM from hemorrhage; given the wellknown GRE hypointensity of hemorrhage. Described signal changes may be relevant in the setting of recent intra-arterial or intravenous ICM administration in translational research and/or human stroke therapy.
推荐文章
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Effects of iodinated contrast on various magnetic resonance imaging sequences and field strength: Implications for characterization of hemorrhagic transformation in acute stroke therapy
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 Iodinated CONTRAST Magnetic resonance imaging Gradient-echo HEMORRHAGE STROKE
年,卷(期) 2016,(6) 所属期刊栏目
研究方向 页码范围 588-593
页数 6页 分类号 R445.2
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2016(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Iodinated
CONTRAST
Magnetic
resonance
imaging
Gradient-echo
HEMORRHAGE
STROKE
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导