AIM: To assess diagnostic image quality of reduced dose(RD) abdominal computed tomography(CT) with 9 iterative reconstruction techniques(IRTs) from 4 different vendors to the standard of care(SD) CT.METHODS: In an Institutional Review Board approved study, 66 patients(mean age 60 ± 13 years, 44 men, and 22 women) undergoing routine abdomen CT on multi-detector CT(MDCT) scanners from vendors A, B, and C(≥ 64 row CT scanners)(22 patients each) gave written informed consent for acquisition of an additional RD CT series. Sinogram data of RD CT was reconstructed with two vendor-specific and a vendor-neutral IRTs(A-1, A-2, A-3; B-1, B-2, B-3; and C-1, C-2, C-3) and SD CT series with filtered back projection. Subjective image evaluation was performed by two radiologists for each SD and RD CT series blinded and independently. All RD CT series(198) were assessed first followed by SD CT series(66). Objective image noise was measured for SD and RD CT series. Data were analyzed by Wilcoxon signed rank, kappa, and analysis of variance tests.RESULTS: There were 13/50, 18/57 and 9/40 missed lesions(size 2-7 mm) on RD CT for vendor A, B, and C, respectively. Missed lesions includes liver cysts, kidney cysts and stone, gall stone, fatty liver, and pancreatitis. There were also 5, 4, and 4 pseudo lesions(size 2-3 mm) on RD CT for vendor A, B, and C, respectively. Lesions conspicuity was sufficient for clinical diagnostic performance for 6/24(RD-A-1), 10/24(RD-A-2), and 7/24(RD-A-3) lesions for vendor A; 5/26(RD-B-1), 6/26(RD-B-2), and 7/26(RD-B-3) lesions for vendor B; and 4/20(RD-C-1) 6/20(RD-C-2), and 10/20(RD-C-3) lesions for vendor C(P = 0.9). Mean objective image noise in liver was significantly lower for RD A-1 compared to both RD A-2 and RD A-3 images(P < 0.001). Similarly, mean objective image noise lower for RD B-2(compared to RD B-1, RD B-3) and RD C-3(compared to RD C-1 and C-2)(P = 0.016).CONCLUSION: Regardless of IRTs and MDCT vendors, abdominal CT acquired at mean CT dose index volume 1.3 m Gy is not sufficient to
推荐文章
SUB条款在租船实务中的运用
SUB条款
租船实务
租船人
出租人
Elemental characteristics and paleoenvironment reconstruction: a case study of the Triassic lacustri
Trace elements
Occurrence mode
Paleoenvironment
Zhangjiatan oil shale
Yanchang Formation
Ordos Basin
一种基于社会学行为的Pub/Sub系统路由
朋友圈
小世界
复杂网络
路由
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Assessment of sub-milli-sievert abdominal computed tomography with iterative reconstruction techniques of different vendors
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 ADULT COMPUTED tomographic imaging ABDOMEN Radiation DOSE
年,卷(期) 2016,(6) 所属期刊栏目
研究方向 页码范围 618-627
页数 10页 分类号 R816.5
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2016(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
ADULT
COMPUTED
tomographic
imaging
ABDOMEN
Radiation
DOSE
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导