基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes, is referred to as the “surgical modality of choice”. While outcomes with each modality are usually good to excellent, each has its share of shortcomings and complications. Thus, there is scope for improvements to existing modalities and/or introduction of new ones. Study Purpose: We introduce a novel modality, namely, the prototype of an intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis (IPBO) system, and investigated its plausibility. Experimental Procedures: The biomechanical performance of a construct comprising a synthetic distal radius (fourth-generation Sawbones?) on which a simulated fracture was created (4-mm wide osteotomy positioned 25 mm from the most distal end of the radius) and fixated with a placement of the IPBO system (SIPBO Construct) was compared to that when the fixation was with an approved Ti-6Al-4V alloy VLP system (SVLP Construct), under a clinically-relevant compressive loading protocol. Performance involved determination of quantitative parameters of the construct (initial longitudinal stiffness (ICLS), final longitudinal stiffness (FCLS), and load-to-failure (Pf)) and observation and recording of features of the construct at the fracture point. We also determined the quantitative parameters for the intact synthetic distal radius (control). Results: For each of the quantitative parameters, the range of values for SIPBO Construct was within that for SVLP Construct, suggesting that the IPBO System is a plausible modality. Also, for SIPBO Construct, failure occurred within the polymer zone, whereas, for SVLP Construct, some failure features were fracture of the cortical wall and of the dorsal proximal fragments. Conclusion: The findings suggest that the IPBO system is plausible. As such, it merits further study;for example, determination
推荐文章
Using Geomechanical Method to Predict Tectonic Fractures in Low-Permeability Sandstone Reservoirs
Low-permeability sandstone reservoir
Fracture parameters
Geomechanical method
基于Anycast技术的RADIUS负载均衡
T-MPLS
MPLS-TP
PTN
分组传送网
构建安全可靠的RADIUS系统
RADIUS
安全防火墙
双机热备
DIAMETER协议和RADIUS协议的比较
RADIUS协议
DIAMETER协议
认证/授权/计费服务器
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Biomechanical Comparison of Prototype of a Novel Intramedullary Injectable Bioresorbable Polymer-Bioresorbable Balloon Osteosynthesis and a Volar Locking Plate for Treatment of Distal Radius Fractures
来源期刊 世界工程和技术(英文) 学科 医学
关键词 Distal Radius Fractures VOLAR Locking Plate INJECTABLE BIORESORBABLE POLYMER BIOMECHANICAL Tests
年,卷(期) 2017,(2) 所属期刊栏目
研究方向 页码范围 309-323
页数 15页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2017(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Distal
Radius
Fractures
VOLAR
Locking
Plate
INJECTABLE
BIORESORBABLE
POLYMER
BIOMECHANICAL
Tests
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界工程和技术(英文)
季刊
2331-4222
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
482
总下载数(次)
0
总被引数(次)
0
论文1v1指导