基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM To investigate changes in polyp detection throughout fellowship training, and estimate colonoscopy volume required to achieve the adenoma detection rate(ADRs) and polyp detection rate(PDRs) of attending gastroenterologists.METHODS We reviewed colonoscopies from July 1, 2009 to June 30, 2014. Fellows’ procedural logs were used to retrieve colonoscopy procedural volumes, and these were treated as the time variable. Findings from screening colonoscopies were used to calculate colonoscopy outcomes for each fellow for the prior 50 colonoscopies at each time point. ADR and PDR were plotted against colonoscopy procedural volumes to produce individual longitudinal graphs. Repeated measures linear mixed effects models were used to study the change of ADR and PDR with increasing procedural volume.RESULTS During the study period, 12 fellows completed full three years of training and were included in the analysis. The average ADR and PDR were, respectively, 31.5% and 41.9% for all fellows, and 28.9% and 38.2% for attendings alone. There was a statistically significant increase in ADR with increasing procedural volume(1.8%/100 colonoscopies, P = 0.002). Similarly, PDR increased 2.8%/100 colonoscopies(P = 0.0001), while there was no significant change in advanced ADR(0.04%/100 colonoscopies, P = 0.92). The ADR increase was limited to the right side of the colon, while the PDR increased in both the right and left colon. The adenoma per colon and polyp per colon also increased throughout training. Fellows reached the attendings’ ADR and PDR after 265 and 292 colonoscopies, respectively.CONCLUSION We found that the ADR and PDR increase with increasing colonoscopy volume throughout fellowship. Our findings support recent recommendations of ≥ 275 colonoscopies for colonoscopy credentialing.
推荐文章
基于Object Detection API的物流单元货架目标检测
深度学习
物流单元货架
目标检测
Faster R-CNN算法
SSD-MobileNet算法
Smiths Detection推出新款空运货物扫描机
扫描机
货物
空运
检测系统
托盘尺寸
运输安全
操作人员
信息扫描
基于谷歌TensorFlow Object Detection的"智慧"分类垃圾桶设计
垃圾智能分类
谷歌TensorFlow
Object Detection
python
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Colonoscopy procedural volume increases adenoma and polyp detection rates in gastroenterology trainees
来源期刊 世界胃肠内镜杂志:英文版(电子版) 学科 医学
关键词 屏蔽 colonoscopy Colorectal 癌症 息肉察觉率 Colonoscopy 体积 腺瘤察觉率 肠胃病学训练
年,卷(期) 2017,(11) 所属期刊栏目
研究方向 页码范围 540-551
页数 12页 分类号 R-4
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2017(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
屏蔽
colonoscopy
Colorectal
癌症
息肉察觉率
Colonoscopy
体积
腺瘤察觉率
肠胃病学训练
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界胃肠内镜杂志:英文版(电子版)
月刊
1948-5190
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
557
总下载数(次)
0
总被引数(次)
0
论文1v1指导