AIM To examine effects of computed tomography(CT)image acquisition/reconstruction parameters on clot volume quantification in vitro for research method validation purposes.METHODS This study was performed in conformance with HIPAA and IRB Regulations(March 2015-November 2016).A ten blood clot phantom was designed and scanned on a dual-energy CT scanner(SOMATOM Force,Siemens Healthcare GmBH,Erlangen,Germany)with varying pitch,iterative reconstruction,energy level and slice thickness.A range of clot and tube sizes were used in an attempt to replicate in vivo emboli found within central and segmental branches of the pulmonary arteries in patients with pulmonary emboli.Clot volume was the measured parameter and was analyzed by a single image analyst using a semi-automated region growing algorithm implemented in the FDA-approved Siemens syngo.via image analysis platform.Mixed model analysis was performed on the data.RESULTS On the acquisition side,the continuous factor of energy showed no statistically significant effect on absolute clot volume quantification(P=0.9898).On the other hand,when considering the fixed factor of pitch,there were statistically significant differences in clot volume quantification(P<0.0001).On the reconstruction side,with the continuous factor of reconstruction slice thickness no statistically significant effect on absolute clot volume quantification was demonstrated(P=0.4500).Also on the reconstruction side,with the fixed factor of using iterative reconstructions there was also no statistically significant effect on absolute clot volume quantification(P=0.3011).In addition,there was excellent R2 correlation between the scale-measured mass of the clots both with respect to the CT measured volumes and with respect to volumes measure by the water displacement method.CONCLUSION Aside from varying pitch,changing CT acquisition parameters and using iterative reconstructions had no significant impact on clot volume quantification with a semi-automated region growing algorithm.
推荐文章
基于GPU实现SlideShow中的effect和transition
图像处理器
Direct3D
SlideShow
固定功能流水线
可编程流水线
高级渲染语言
顶点渲染
像素渲染
First-principles investigation of the concentration effect on equilibrium fractionation of Ca isotop
Ca isotope
First-principles calculations
Forsterite
Concentration effect
Equilibrium isotope fractionation
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Effect of varying computed tomography acquisition and reconstruction parameters on semi-automated clot volume quantification
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 Computed tomography angiography RADIOGRAPHIC PHANTOM COMPUTER-ASSISTED image analysis Pulmonary EMBOLISM THROMBOLYTIC therapy
年,卷(期) 2018,(3) 所属期刊栏目
研究方向 页码范围 24-29
页数 6页 分类号 R
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Computed
tomography
angiography
RADIOGRAPHIC
PHANTOM
COMPUTER-ASSISTED
image
analysis
Pulmonary
EMBOLISM
THROMBOLYTIC
therapy
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导