基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Introduction: We have previously developed an effective atomic number (Zeff) measurement method using linear attenuation coefficients (LACs) obtained by energy-resolved computed tomography (CT) with one-dimensional (1D) detector. The energy-resolved CT was performed with a “transXend” detector, which measured X-rays as electric current and then gave X-ray energy distribution with unfolding analysis using pre-estimated response function (RF). The purpose of this study is to measure Zeff by the energy-resolved CT using a flat panel detector (FPD). Methods: To demonstrate a 2D transXend detector, we developed the stripe absorbers for the FPD. Eleven human tissue-equivalent material rods which were grouped into four material categories were measured by X-rays with 120 kVp tube voltage, 2.3 mA tube current, and 1.0 s exposure time. Zeff is measured by the ratio of LACs with two different pseudo-monochromatic X-ray energies. RFs of each rod material were estimated by numerical calculation. First, we employed the RF estimated for the same rod material (self-RF scenario). Second, we employed the RF estimated for the different rod materials in the same material category (cross-RF scenario). The purpose of the cross-RF scenario was to find representative rod materials in each material category. Results: Upon the self-RF scenario, measured Zeffs were systematically underestimated. Median relative error to theoretical Zeff was -6.92% (range: -7.89% - -4.60%). After normalizing measured Zeffs to the theoretical one for Breast, median relative error improved to -0.75% (range: -1.79% - +1.73%). Upon the cross-RF scenario, the representative rod materials were found in two material categories. Conclusion: Zeff measurements were performed by energy-resolved CT using 2D transXend detector with numerically-estimated RF data. Normalized Zeffs for all rod materials in the self-RF scenario were in good agreement with the theoretical ones.
推荐文章
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Effective Atomic Number Measurement with Energy-Resolved Computed Tomography Using Two-Dimensional “transXend” Detector
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 X-Ray COMPUTED TOMOGRAPHY ENERGY RESOLVED UNFOLDING Effective Atomic Number
年,卷(期) 2018,(1) 所属期刊栏目
研究方向 页码范围 61-73
页数 13页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
X-Ray
COMPUTED
TOMOGRAPHY
ENERGY
RESOLVED
UNFOLDING
Effective
Atomic
Number
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导