基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
We investigated the longitudinal positional dependence of CT number in 320-row Cone Beam Computed Tomography (CBCT) volume scan (320-row volume scan) using a simple geometric phantom (SGP) and a chest simulation phantom (CSP) in order to evaluate its effect on proton range calculation. The SGP consisted of lung substitute material (LSM) and a cylindrical phantom (CP) made of high-density polyethylene. The CSP was an anthropomorphic phantom similar to the human chest. The two phantoms were scanned using 320-row volume scan in various longitudinal positions from the central beam axis. In experiments using the SGP, an image blur at the boundary of the two materials became gradually evident when the LSM was placed far away from the beam central axis. The image blur of the phantom was consistent with the gradation in CT number. The maximum difference in CT numbers between the 64-row helical scan and 320-row volume scan at the boundary of the two materials was consistent with approximately 50% of the relative proton stopping power. In contrast, the CT number profile in each longitudinal position was fairly consistent and longitudinal positional dependence rarely occurred in the CSP experiments. Pass lengths of CT beams through areas with widely different electron densities were shorter, and thus did not significantly impact CT numbers. Based on findings from the CSP experiments, we considered 320-row volume scan to be feasible for proton range calculation in clinical settings, although the relatively large longitudinal positional dependence of CT number should be accounted for when doing so.
推荐文章
基于卷积神经网络CT/CBCT影像质量自动分析
卷积神经网络
CT
锥形束CT
图像质量
自动分析
GPU框架下基于改进Demons算法的CT-CBCT图像变形配准研究
Demons算法
图像变形配准
GPU加速
CUDA语言
CT与CBCT图像配准范围选择的对比研究
影像引导的放疗
CBCT
图像配准
互信息
CBCT用于腹盆部恶性肿瘤放疗摆位误差分析
IGRT
IMRT
CBCT
腹盆部肿瘤
摆位误差
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Experimental Evaluation of CT Number Changes in 320-Row CBCT Volume Scan for Proton Range Calculation
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 320-Row CBCT VOLUME SCAN CT Number PROTON RANGE Relative Stopping Power
年,卷(期) 2018,(2) 所属期刊栏目
研究方向 页码范围 141-150
页数 10页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
320-Row
CBCT
VOLUME
SCAN
CT
Number
PROTON
RANGE
Relative
Stopping
Power
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导