The accuracy of conventional superposition or convolution methods for scatter correction in kV-CBCT is usually compromised by the spatial variation of pencil-beam scatter kernel (PBSK) due to finite size, irregular external contour and heterogeneity of the imaged object. This study aims to propose an analytical method to quantify the Compton single scatter (CSS) component of the PBSK, which dominates the spatial distribution of total scatter assuming that multiple scatter can be estimated as a constant background and Rayleigh scatter is the secondary source of scatter. The CSS component of PBSK is the line integration of scatter production by incident primary photons along the beam line followed by the post-scattering attenuation as the scattered photons traverse the object. We propose to separate the object-specific attenuation term from the line integration and equivalently replace it with an average value such that the line integration of scatter production is object independent but only beam specific. We derived a quartic function formula as an approximate solution to the spatial distribution of the unattenuated CSS component of PBSK. The “effective scattering center” is introduced to calculate the average attenuation. The proposed analytical framework to calculate the CSS was evaluated using parameter settings of the On-Board Imager kV-CBCT system and was found to be in high agreement with the reference results. The proposed method shows highly increased computational efficiency compared to conventional analytical calculation methods based on point scattering model. It is also potentially useful for correcting the spatial variant PBSK in adaptive superposition method.
推荐文章
基于ModBus通讯协议的Scatter I/O优化方法
ModBus通讯协议
组态软件
Scatter I/O
KV-CBCT对头颈部肿瘤治疗摆位误差及靶区物理剂量学的影响
KV-CBCT
头颈部肿瘤
摆位误差
物理剂量学
KV-KV、KV-MV和CBCT在头颈部调强放疗位置验证中的对比研究
头颈部调强
位置验证
锥形束CT
千伏
兆伏
比较
机载KV-CBCT在乳腺癌调强放射治疗误差分析中的应用
乳腺肿瘤
锥形束CT
调强放疗
乳腺托架
摆位误差
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Analytical Calculation of the Compton Single Scatter Component of Pencil Beam Scatter Kernel for Scatter Correction in kV Cone Beam CT (kV-CBCT)
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 SCATTER Correction Cone BEAM CT BEAM SCATTER KERNEL COMPTON SCATTER SINGLE SCATTER
年,卷(期) 2018,(2) 所属期刊栏目
研究方向 页码范围 214-230
页数 17页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
SCATTER
Correction
Cone
BEAM
CT
BEAM
SCATTER
KERNEL
COMPTON
SCATTER
SINGLE
SCATTER
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导