基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
We study a general framework for assessing the injury probability corresponding to an input dose quantity. In many applications, the true value of input dose may not be directly measurable. Instead, the input dose is estimated from measurable/controllable quantities via numerical simulations using assumed representative parameter values. We aim at developing a simple modeling framework for accommodating all uncertainties, including the discrepancy between the estimated input dose and the true input dose. We first interpret the widely used logistic dose-injury model as the result of dose propagation uncertainty from input dose to target dose at the active site for injury where the binary outcome is completely determined by the target dose. We specify the symmetric logistic dose-injury function using two shape parameters: the median injury dose and the 10 - 90 percentile width. We relate the two shape parameters of injury function to the mean and standard deviation of the dose propagation uncertainty. We find 1) a larger total uncertainty will spread more the dose-response function, increasing the 10 - 90 percentile width and 2) a systematic over-estimate of the input dose will shift the injury probability toward the right along the estimated input dose. This framework provides a way of revising an established injury model for a particular test population to predict the injury model for a new population with different distributions of parameters that affect the dose propagation and dose estimation. In addition to modeling dose propagation uncertainty, we propose a new 3-parameter model to include the skewness of injury function. The proposed 3-parameter function form is based on shifted log-normal distribution of dose propagation uncertainty and is approximately invariant when other uncertainties are added. The proposed 3-parameter function form provides a framework for extending skewed injury model from a test population to a target population in application.
推荐文章
一体式定位像和分段式定位像配合CARE Dose 4D技术控制PET检查者辐射剂量的比较
定位像
自动管电流调节技术
正电子发射计算机断层显像
计算机断层扫描
剂量长度乘积
CT容积剂量指数
CARE Dose4D技术在肝脏扫描中的应用
双源CT
CARE Dose 4D
肝脏扫描
辐射剂量
用CARE Dose4D技术进行胸部扫描的临床价值
胸部
螺旋CT
CARE Dose4D
辐射防护
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Dose-Injury Relation as a Model for Uncertainty Propagation from Input Dose to Target Dose
来源期刊 美国运筹学期刊(英文) 学科 医学
关键词 DOSE INJURY RELATION DOSE Propagation Uncertainty MEDIAN INJURY DOSE 10 - 90 Percentile Width SKEWNESS Mapping INJURY MODEL from One Population to Another
年,卷(期) 2018,(5) 所属期刊栏目
研究方向 页码范围 360-385
页数 26页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
DOSE
INJURY
RELATION
DOSE
Propagation
Uncertainty
MEDIAN
INJURY
DOSE
10
-
90
Percentile
Width
SKEWNESS
Mapping
INJURY
MODEL
from
One
Population
to
Another
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
美国运筹学期刊(英文)
半月刊
2160-8830
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
329
总下载数(次)
0
总被引数(次)
0
论文1v1指导