基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Background: Distortion of the Leksell stereotactic frame can occur during surgical and radiosurgical frame-based procedures. The targeting accuracies of surgical procedures such as DBS surgery or frame-based biopsy, or Gamma Knife radiosurgical procedures, are related to the stereotactic frame that is commonly referred to a non-deformable referential system. Objective: To evaluate the clinical impact of frame distortion on accuracy of targeting in various stereotactic procedures. Methods: We studied the influence of increasing levels of distortion of the Leksell frame both on surgical procedures using the stereotactic arch, and on radiosurgical procedures with the Gamma Knife. For surgical procedures we applied the Target Simulator of Elekta to a frame submitted to different levels of frame distortion, and we measured the modifications of accuracy of targeting. For radiosurgical procedures the Leksell frame was applied on an anthropomorphic phantom and modifications of target coordinates were measured by an imaging method using the stereotactic CBCT of the Gamma Knife ICON. Results: For surgical procedures, we found a linear relation between the amount of the frame distortion and the extent of the deviation from the stereotactic target using the stereotactic arch (R2 = 0.99709). The level of bending of the frame is also linearly related to the level of inaccuracy of stereotactic targeting based on acquisition of MRI and CTscan with the Elekta imaging boxes (R2 = 0.96825). The inaccuracy of targeting related to frame bending can be avoided by a systematic control at the end of frame placement and by the use of the CBCT of the Gamma Knife Icon. Conclusion: Distortion of the frame is a significant source of clinical inaccuracy of targeting for stereotactic procedures. Frame bending must be checked after each frame placement and corrected if needed to avoid targeting inaccuracy during stereotactic surgery and radio-surgery procedures.
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Clinical Impact of Targeting Inaccuracy Due to Distortion of the Leksell Stereotactic Frame
来源期刊 现代神经外科学进展(英文) 学科 医学
关键词 TARGETING Inaccuracy DISTORTION FRAME STEREOTACTIC
年,卷(期) 2018,(3) 所属期刊栏目
研究方向 页码范围 315-322
页数 8页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
TARGETING
Inaccuracy
DISTORTION
FRAME
STEREOTACTIC
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
现代神经外科学进展(英文)
季刊
2163-0569
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
246
总下载数(次)
0
总被引数(次)
0
论文1v1指导