基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Although pulsatile ECMO,as novel kinds of ECMO,has been attracted more and more attention,the differences of the hemodynamic effects of the pulsatile ECMO on the aorta,the cerebral perfusion,and left ventricular work were still under-investigated.The aim of this study was to clarify the hemodynamic differences of the cardiovascular system between the pulsatile and non-pulsatile VA ECMO.In this study,three ECMO support modes,named as“constant flow mode”,“co-pulse mode”and“counter pulse mode”,were designed.The computational fluid dynamics(CFD)study was carried out.The distribution of the oxygenated blood,the blood velocity vector,the oscillatory shear index(OSI),the relative residence time(RRT),the left ventricular external work(EW),the equivalent left ventricular afterload(EAL)and the energy loss of cardiovascular system(EL)were calculated to compare the hemodynamic differences.The simulation results demonstrate that the oxygenated blood under co-pulse mode was easier to perfuse into the three braches vessels than that under both other modes.In addition,the ECMO under counter pulse mode could also achieve lowest RRT(constant flow mode 220 vs.co-pulse mode 132 vs.counter pulse mode 93).Similarly,the ECMO under counter pulse mode could significantly reduce the left ventricular external work(co-pulse mode 1.51 w vs.constant flow mode 1.44 w and counter pulse mode 1.30 w),left ventricular afterload(constant flow mode 1.03 mmHg·s/ml vs.co-pulse mode 1.67 mmHg·s/ml vs.counter pulse mode 0.82 mmHg·s/ml)and energy loss of arterial system(constant flow mode 0.18 w vs.co-pulse mode 0.50 w vs.counter pulse mode 0.16 w).In short,the ECMO under counter pulse mode could have advantages to the left ventricular unloading.In contrast,the ECMO under co-pulse mode has more benefit to cerebral oxygen perfusion.
推荐文章
An experimental study of interaction between pure water and alkaline feldspar at high temperatures a
Alkaline feldspar
Autoclave
High-temperature and high-pressure experiments
Incorporation of silica into the goethite structure: a microscopic and spectroscopic study
Quartz
Goethite
Twinned goethite
Microscopic characterization (FESEM and TEM)
FT-IR spectroscopy
Elemental characteristics and paleoenvironment reconstruction: a case study of the Triassic lacustri
Trace elements
Occurrence mode
Paleoenvironment
Zhangjiatan oil shale
Yanchang Formation
Ordos Basin
Soil organic carbon dynamics study bias deduced from isotopic fractionation in corn plant
Bias of SOC dynamics study
Isotopic fractionation in corn
Isotope mass balance equation
Bias range
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 The Hemodynamic Comparative Study Between Pulsatile and Non-Pulsatile VA ECMO:A Primary Numerical Study
来源期刊 工程与科学中的计算机建模(英文) 学科 医学
关键词 PULSATILE non-pulsatile VA ECMO hemodynamics CFD
年,卷(期) 2018,(8) 所属期刊栏目
研究方向 页码范围 247-262
页数 16页 分类号 R54
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
PULSATILE
non-pulsatile
VA
ECMO
hemodynamics
CFD
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
工程与科学中的计算机建模(英文)
月刊
1526-1492
江苏省南京市浦口区东大路2号东大科技园A
出版文献量(篇)
299
总下载数(次)
1
总被引数(次)
0
论文1v1指导