AIM: To validate the ability of the Heidelberg Edge Perimeter (HEP) in detecting glaucomatous visual field (VF) defects compared to the Octopus Visual Field (OVF) Analyzer and to determine the test-retest repeatability of both modalities. METHODS: This prospective, cross-sectional study was conducted at Wills Eye Hospital, Philadelphia, PA. Glaucoma subjects and unaffected controls underwent VF testing using HEP standard automated perimetry (SAP) III 30-2 Adaptive Staircase Thresholding Algorithm (ASTA) FAST protocol and OVF G-TOP white-on-white strategy. Testing order was randomized. Pearson’s correlation coefficient was calculated for both mean deviation (MD) and pattern standard deviation/square root of loss of variance (PSD/sLV). Receiver operating characteristic (ROC) curves were used to determine the diagnostic abilities of both modalities. Glaucoma subjects returned for repeat testing and intraclass correlation coefficients (ICCs) were calculated to assess test-retest repeatability. RESULTS: Seventy-nine subjects with glaucoma and 36 unaffected controls were enrolled. HEP and OVF were significantly correlated for both MD (r=-0.84;P<0.01) and PSD/sLV (r=0.79;P<0.01). Areas under the ROC curves (AUCs) were also comparable between HEP and OVF for both MD (0.74 and 0.79, respectively;P=0.26) and PSD/sLV (0.74 and 0.82;P=0.08). ICC was high for both HEP (0.96 for MD, 0.95 for PSD/sLV) and OVF (0.82 and 0.88, respectively). Mean test duration (min) was significantly shorter for OVF (2.63) compared to HEP (5.15;P<0.01). CONCLUSION: HEP and OVF show strong correlation for both MD and PSD/sLV, and have similar validity for detecting glaucoma. The test-retest repeatability is high for both HEP and OVF, however the average testing duration of HEP is significantly longer than that of OVF.
推荐文章
基于Solid Edge采用Visual Basic开发塑料模标准件库
模具标准件库
Solid
Edge
二次开发
Forest carbon storage in Guizhou Province based on field measurement dataset
Forest carbon storage
Field measurement dataset
Karst landform
基于Solid Edge的塑料模标准件库的系统开发方法
模具标准件库
Solid Edge
二次开发
程序驱动法
数据处理与传递
基于Cross-Validation的小波自适应去噪方法
小波变换
Cross-Validation
自适应滤波
闽值
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Validation and reproducibility of the Heidelberg Edge Perimeter in the detection of glaucomatous visual field defects
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 glaucoma HEIDELBERG EDGE PERIMETER standard automated PERIMETRY Octopus VISUAL FIELD Analyzer VISUAL FIELD
年,卷(期) gjykzzywb_2019,(4) 所属期刊栏目
研究方向 页码范围 577-581
页数 5页 分类号 R
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
glaucoma
HEIDELBERG
EDGE
PERIMETER
standard
automated
PERIMETRY
Octopus
VISUAL
FIELD
Analyzer
VISUAL
FIELD
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
论文1v1指导