基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
A challenge faced by protection and planning engineers is the development and validation of accurate wind turbine generator(WTG)models to study the impact of increasing wind integration on system protection.Thispaper is on the experimental validation of a generic electromagnetic transient-type(EMT-type)model of aggregated WTGs or wind parks suitable for transient studies.The phasor domain equivalent of the generic model,suitable for protection tools based on steady-state solvers,is also considered.The model has been validated using two sets of actual relay records for the fault response of two wind parks consisting of Type-III WTGs and connected to115 kV and 230 kV transmission systems.The objective is to show that the generic model can reproduce the actual fault response in simulations,and protection engineers can obtain accurate models of wind parks using fault records.A distinctive characteristic of a WTG is its substantially different negative sequence fault current contribution compared to a synchronous generator.The paper shows that the generic model provides enough options to reproduce the negative sequence behavior and hence is suitable for fault studies involving negative sequence-based protection.
推荐文章
Spatial prediction of landslide susceptibility using GIS-based statistical and machine learning mode
Landslide susceptibility mapping
Statistical model
Machine learning model
Four cases
Determination of brominated diphenyl ethers in atmospheric particulate matter using selective pressu
Brominated diphenyl ethers
Atmospheric particulate matters
Selective pressurised liquid extraction
Gas chromatography-mass spectrometry
Forest carbon storage in Guizhou Province based on field measurement dataset
Forest carbon storage
Field measurement dataset
Karst landform
Diagenetic evolution of clastic reservoirs and its records in fine subsection: significance and appl
Tight sandstone reservoirs
Diagenetic evolution
Fine subsection
Significance
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Field validation of generic wind park models using fault records
来源期刊 现代电力系统与清洁能源学报(英文) 学科 工学
关键词 Renewable generation WIND turbine GENERATOR DOUBLY-FED induction GENERATOR SHORT-CIRCUIT analysis Electromagnetic transient-type MODEL PHASOR domain MODEL
年,卷(期) 2019,(4) 所属期刊栏目
研究方向 页码范围 826-836
页数 11页 分类号 TM614
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Renewable
generation
WIND
turbine
GENERATOR
DOUBLY-FED
induction
GENERATOR
SHORT-CIRCUIT
analysis
Electromagnetic
transient-type
MODEL
PHASOR
domain
MODEL
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
现代电力系统与清洁能源学报(英文)
双月刊
2196-5625
32-1884/TK
No. 19 Chengxin Aven
出版文献量(篇)
386
总下载数(次)
0
总被引数(次)
0
论文1v1指导