基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
To guarantee a reliable power supply,the expected operation of all the components in the power system is critical.Distance protection system is primarily responsible of isolating the faulty section from the healthy part for the grid.Failure in protection devices can result in multiple conflicting alarms at the power grid operation center and complex event analysis to manually find the root cause of the observed system state.If not handled in time,it may lead to the propagation of the faults/failures to the adjacent transmission lines and components.With availability of the synchronized measurements from phasor measurement units(PMUs),real-time system monitoring and automated failure diagnosis are feasible.With multiple adverse events and possible data anomalies,the complexity of the problem will be escalated.In this paper,a PMUbased algorithm is presented and discussed to detect the root cause of the failure in transmission protection system based on the observed state,e.g.multiple line tripping andbreaker failures.The failure diagnosis algorithm is further enhanced to come up with the fully functional version of the failure diagnosis tool,which is tailored for the cases in which the PMU anomalies are present.In the developed algorithm,the validity of the PMU data is critical.However,such causes as communication errors or cyber-attacks might lead to the PMU data anomalies.This issue is welladdressed in this paper and some major types of anomaly detection methods suitable for PMU data are discussed.Results show that the ensemble approach has some distinct advantages in data anomaly detection compared to the previously used standalone algorithms.Additionally,the enhanced failure diagnosis method is developed to clean the inaccurate data in case of the anomaly in measured voltage magnitudes.Finally,both original and enhanced versions of the tool are tested on 96-bus test system using the real-time OPAL-RT simulator.The results show the accuracy of the enhanced tool and its advantages over the primary version of the
推荐文章
基于语义的Data Cube数字水印技术
数字水印
语义
数据立方体
版权
Data Transfer Object模式探讨
Data Transfer Object 三层应用 DataSet
Statistics matters in interpretations of non-traditional stable isotopic data
Isotopic data processing
Error propagation
Significant digits
Difference between means with uncertainties
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Data-driven failure diagnosis in transmission protection system with multiple events and data anomalies
来源期刊 现代电力系统与清洁能源学报(英文) 学科 工学
关键词 Failure diagnosis TRANSMISSION PROTECTION system PROTECTION mis-operation PHASOR measurement unit(PMU) DATA anomaly and cleaning Ensemble method
年,卷(期) 2019,(4) 所属期刊栏目
研究方向 页码范围 767-778
页数 12页 分类号 TM933.313
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Failure
diagnosis
TRANSMISSION
PROTECTION
system
PROTECTION
mis-operation
PHASOR
measurement
unit(PMU)
DATA
anomaly
and
cleaning
Ensemble
method
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
现代电力系统与清洁能源学报(英文)
双月刊
2196-5625
32-1884/TK
No. 19 Chengxin Aven
出版文献量(篇)
386
总下载数(次)
0
总被引数(次)
0
论文1v1指导