基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Purpose: Standardization of tumor dosimetric coverage is essential for the evaluation of radiotherapy treatment plan quality. National clinical trials network RTOG protocols include tumor target dosimetric criteria that specify the prescription dose and minimum and maximum dose (Dmin and Dmax) coverages. This study investigated the impact of various minimum and maximum dose definitions using tumor control probability (TCP) models. Methods and Materials: Three disease sites (head and neck, lung, and prostate) were studied using target volume dosimetric criteria from the RTOG 0920, 1308, and 0938 protocols. Simulated target dose-volume histograms (DVHs) of Dmin and Dmax were modeled using the protocol specifications. Published TCP models for the three disease sites were applied to the DVH curves. The effects of various dose definitions on TCP were studied. Results: While the prescription dose coverage was maintained, a -3.7% TCP difference was observed for head and neck cancer when the target doses varied by 3.5% of the tumor volume from the point dose. For prostate and lung cancers, -3.3% and -2.2% TCP differences were observed, respectively. The TCPs for head and neck and prostate cancers were more negatively affected by deviations in the Dmin than the TCP for lung cancer. The lung TCP increased to a greater extent with a change in the Dmax compared with the head and neck and prostate TCPs. Conclusions: These results can be used to evaluate plan quality when the target dose only slightly deviates from the dosimetric criteria. When the overall target prescription dose coverage is maintained, the Dmax is recommended to be within 3% of the target volume: 98% (for head and neck and prostate) and 97% (for lung) of the target volume, satisfying the Dmin needed to maintain TCP variations at less than 2.1%. Using 0.03 cc instead of a point dose for Dmin and Dmax criteria minimally impacts TCPs.
推荐文章
Evaluation of groundwater quality in the Dibdibba aquifer using hydrogeochemical and isotope techniq
Safwan-Zubair
Dibdibba formation
Geochemical modeling
Mixing
Stable isotopes
Basra
基于xPC Target的采集卡驱动程序开发
xPCTarget
实时仿真
驱动
S函数
基于xPC Target和iHawk的飞行控制实时仿真系统设计与实现
iHawk
xPC Target
快速原型控制
硬件在回路
实时仿真
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Investigation of Target Minimum and Maximum Dosimetric Criteria for the Evaluation of Standardized Radiotherapy Plan <br/>—Target Minimum and Maximum Evaluation
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 Rodiotherapy TARGET Dosimetric CRITERIA
年,卷(期) 2020,(2) 所属期刊栏目
研究方向 页码范围 43-51
页数 9页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Rodiotherapy
TARGET
Dosimetric
CRITERIA
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导