作者:
基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Modern medicine is unthinkable without X-rays. Accurate diagnosis, leading to effective treatment, is largely based on precise X-ray examinations. The creation of new, modern equipment and various medical procedures that meet the increased requirements are a priority in our time. X-ray examinations are of particular importance for the orthopedic and traumatological clinics, where they provide information about presence of a fracture in the patient’s body, about the concrete operation performed or about the effect of a suitable treatment. Along with their benefits X-rays have also a harmful effect. This requires special care to protect from this radiation. In this direction, research is constantly being done to improve the quality of radiation protection. Park MR, Lee KM and co-authors, compare the dose load obtained using C-arm and O-arm X-ray systems (which have the capability of combined 2D fluoroscopy and 3D computed tomography imaging). In their study, an orthopedic surgical procedure using C-arm and O-arm systems in 2D fluoroscopy modes was simulated. The radiation doses to susceptible organs of the operators were investigated. He results obtained show that the O-arm system delivered higher doses to the sensitive organs of the operator in all configurations [1]. The article of Stephen Balte briefly reviews the available technologies for measuring or estimation of patient skin dose in the interventional fluoroscopic environment, created by various X-ray equipment including C-arm systems. Given that many patients require multiple procedures, this documentation also aids in the planning of follow up visits [2]. Chong Hing Wong, Yoshihisa Kotani and co-authors evaluate the radiation exposures (RE) to the patient and surgeon during minimally invasive lumbar spine surgery with instrumentation using C-arm image intensifier or O-arm intraoperative CT. The results they get are in favor of the O-arm system [3]. The article “Virtual fluoroscopy for intraoperative C-arm positioning and radiation dose reduction” di
推荐文章
低能量X-RAY测厚仪与β-RAY
测厚仪
薄膜
应用
比较
高分辨X-RAY成像系统的搭建及其血管造影研究
血管造影
后肢缺血模型
高分辨率X光机
基于X-Ray CT试验的塌陷区回填体孔隙结构研究
地表塌陷区
回填体
X-Ray CT
三维重构
孔隙结构
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Radiation Protection of a Patient Undergoing an Orthopedic Procedure by Using a Mobile C-Arm X-Ray System
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 C-Arm X-Ray Equipment Radiation Protection PATIENT Orthopedics and Traumatology Clinic
年,卷(期) 2020,(3) 所属期刊栏目
研究方向 页码范围 141-156
页数 16页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
C-Arm
X-Ray
Equipment
Radiation
Protection
PATIENT
Orthopedics
and
Traumatology
Clinic
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导