基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
BACKGROUND 7T cardiac magnetic resonance imaging(MRI)introduces several advantages,as well as some limitations,compared to lower-field imaging.The capabilities of ultra-high field(UHF)MRI have not been fully exploited in cardiac functional imaging.AIM To optimize 7T cardiac MRI functional imaging without the need for conducting B1 shimming or subject-specific tuning,which improves scan efficiency.In this study,we provide results from phantom and in vivo scans using a multi-channel transceiver modular coil.METHODS We investigated the effects of adding a dielectric pad at different locations next to the imaged region of interest on improving image quality in subjects with different body habitus.We also investigated the effects of adjusting the imaging flip angle in cine and tagging sequences on improving image quality,B1 field homogeneity,signal-to-noise ratio(SNR),blood-myocardium contrast-to-noise ratio(CNR),and tagging persistence throughout the cardiac cycle.RESULTS The results showed the capability of achieving improved image quality with high spatial resolution(0.75 mm×0.75 mm×2 mm),high temporal resolution(20 ms),and increased tagging persistence(for up to 1200 ms cardiac cycle duration)at 7T cardiac MRI after adjusting scan set-up and imaging parameters.Adjusting the imaging flip angle was essential for achieving optimal SNR and myocardium-toblood CNR.Placing a dielectric pad at the anterior left position of the chest resulted in improved B1 homogeneity compared to other positions,especially in subjects with small chest size.CONCLUSION Improved regional and global cardiac functional imaging can be achieved at 7T MRI through simple scan set-up adjustment and imaging parameter optimization,which would allow for more streamlined and efficient UHF cardiac MRI.
推荐文章
提高焊接7T驱动后桥总成疲劳寿命方法
驱动后桥壳总成
桥壳总成
疲劳寿命
垂直弯曲疲劳断裂
应力集中
7T MRI机房规划原则分析
磁共振
机房规划
信噪比
动态干扰
电磁环境
场分布
颞叶癫在3T与7T MRI上的影像对比及与病理对照分析
颞叶癫日
磁共振成像
超高场强
病理
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Cardiac functional magnetic resonance imaging at 7T:Image quality optimization and ultra-high field capabilities
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 Magnetic resonance imaging HIGH-FIELD Cardiac function CINE Tagging STRAIN
年,卷(期) 2020,(10) 所属期刊栏目
研究方向 页码范围 231-246
页数 16页 分类号 R54
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Magnetic
resonance
imaging
HIGH-FIELD
Cardiac
function
CINE
Tagging
STRAIN
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导