Background::Applying ultrasonic imaging system during surgery requires the poring of saline, performing the measurement, and acquiring data from its display—which requires time and is highly "performer dependent," i.e., the measure is of a subjective nature. A new ultrasonic device was recently developed that overcomes most of these drawbacks and was successfully applied during tumor-in-brain neurosurgeries. The purpose of this study was to compare the two types of US devices and demonstrate their properties.Methods::The study was performed in the following stages: (i) an ex vivo experiment, where slices of the muscle and brain of a young porcine were laid one on top the other. Thicknesses and border depths were measured and compared, using the two types of US instruments. (ii) During human clinical neurosurgeries, tumor depth was compared by measuring it with both devices. (iii) Following the success of stages (i) and (ii), using solely the new US device, the tumor thickness was monitored while its resection. Correlation, Pearson’s coefficient, average, mean, and standard deviation were applied for statistical tests.Results::A high correlation was obtained for the distances of tissue borders and for their respective thicknesses. Applying these ultrasonic devices during neurosurgeries, tumor depths were monitored with high similarity (87%), which was also obtained by Pearson’s correlation coefficient (0.44). The new US device, thanks to its small footprint, its remote measurement, and the capability of monitoring intraoperatively and in real-time, provides the approach to tumor’s border before its complete resection.Conclusions::The new US device provides better accuracy than an ultrasonic imaging system; its data is objective; it enables to control the residual tumor thickness during its resection, and it is especially useful in restricted areas. These features were found of great help during a tumor-in-brain surgery and especially in the final stages of tumor’s resection.
推荐文章
关于I级分类试验的10/350 us波形研究分析
10/350 us波形
雷电参数
正极性地闪
防雷
US-APWR核电厂设计技术方案研究
核电厂
APWR
US-APWR
技术方案
儿童肾母细胞瘤IVP.US.CT.诊断对照研究
肾母细胞瘤
静脉肾盂造影
超声
断层摄影术
US/H2O2系统协同降解苯酚的动力学研究
超声波/过氧化氢
苯酚
协同效应
动力学
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 New US device versus imaging US to assess tumor-in-brain
来源期刊 中华神经外科杂志(英文) 学科
关键词 Neurosurgery Tumor Ultrasound Pulse-echo Residual thickness
年,卷(期) 2020,(4) 所属期刊栏目 Research
研究方向 页码范围 211-223
页数 13页 分类号
字数 语种 中文
DOI 10.1186/s41016-020-00205-1
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (12)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
1965(1)
  • 参考文献(1)
  • 二级参考文献(0)
2001(1)
  • 参考文献(1)
  • 二级参考文献(0)
2002(1)
  • 参考文献(1)
  • 二级参考文献(0)
2003(1)
  • 参考文献(1)
  • 二级参考文献(0)
2005(2)
  • 参考文献(2)
  • 二级参考文献(0)
2006(1)
  • 参考文献(1)
  • 二级参考文献(0)
2010(1)
  • 参考文献(1)
  • 二级参考文献(0)
2014(1)
  • 参考文献(1)
  • 二级参考文献(0)
2015(1)
  • 参考文献(1)
  • 二级参考文献(0)
2016(1)
  • 参考文献(1)
  • 二级参考文献(0)
2017(1)
  • 参考文献(1)
  • 二级参考文献(0)
2020(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Neurosurgery
Tumor
Ultrasound
Pulse-echo
Residual thickness
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
中华神经外科杂志(英文)
季刊
2095-9370
10-1275/R
北京市丰台区南四环西路119号B区613室
2014
eng
出版文献量(篇)
235
总下载数(次)
0
总被引数(次)
24
论文1v1指导