The divertor target components for the Chinese fusion engineering test reactor (CFETR) and the future experimental advanced superconducting tokamak (EAST) need to remove a heat flux of up to ~20 MW m-2.In view of such a high heat flux removal requirement,this study proposes a conceptual design for a flat-tile divertor target based on explosive welding and brazing technology.Rectangular water-cooled channels with a special thermal transfer structure (TTS)are designed in the heat sink to improve the flat-tile divertor target's heat transfer performance(HTP).The parametric design and optimization methods are applied to study the influence of the TTS variation parameters,including height (H),width (W*),thickness (T),and spacing (L),on the HTP.The research results show that the flat-tile divertor target's HTP is sensitive to the TTS parameter changes,and the sensitivity is T > L > W* > H.The HTP first increases and then decreases with the increase of T,L,and W* and gradually increases with the increase of H.The optimal design parameters are as follows:H =5.5 mm,W* =25.8 mm,T =2.2 mm,and L =9.7 mm.The HTP of the optimized flat-tile divertor target at different flow speeds and tungsten tile thicknesses is studied using the numerical simulation method.A flat-tile divertor mock-up is developed according to the optimized parameters.In addition,high heat flux (HHF)tests are performed on an electron beam facility to further investigate the mock-up HTP.The numerical simulation calculation results show that the optimized flat-tile divertor target has great potential for handling the steady-state heat load of 20 MW m-2 under the tungsten tile thickness<5 mm and the flow speed ≥7 m s-1.The heat transfer efficiency of the flat-tile divertor target with rectangular cooling channels improves by ~ 13% and ~30% compared to that of the flat-tile divertor target with circular cooling channels and the ITER-like monoblock,respectively.The HHF tests indicate that the flat-tile divertor mock-up can successfully withstand 1000 cycles of 20 MW m-2 of heat load without visible deformation,damage,and HTP degradation.The surface temperature of the flat-tile divertor mock-up at the 1000th cycle is only ~930 ℃.The fiat-tile divertor target's HTP is greatly improved by the parametric design and optimization method,and is better than the ITER-like monoblock and the fiat-tile mock-up for the WEST divertor.This conceptual design is currently being applied to the engineering design of the CFETR and EAST flat-tile divertors.
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Conceptual design and heat transfer performance of a flat-tile water-cooled divertor target
来源期刊 等离子体科学和技术(英文版) 学科
关键词
年,卷(期) 2021,(9) 所属期刊栏目 FUSION ENGINEERING
研究方向 页码范围 194-205
页数 12页 分类号
字数 语种 英文
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2021(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
等离子体科学和技术(英文版)
月刊
1009-0630
34-1187/TL
大16开
合肥 中国科学院等离子体物理研究所PST编辑部
1999
eng
出版文献量(篇)
3310
总下载数(次)
0
  • 期刊分类
  • 期刊(年)
  • 期刊(期)
  • 期刊推荐
论文1v1指导