基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Objective: To investigate the correlation between Microfibrillar-associated protein 4 (MFAP4) and recurrence and clinical outcome of atrial fibrillation (AF) after radiofrequency catheter ablation (RFCA). Methods: A total of 101 patients with AF admitted to our department from December 2018 to January 2020 were treated with RFCA. The average follow-up period was (11.91 ± 0.38) months. They were divided into recurrence group and non-recurrence group according to whether they had recurrence of AF. The levels of MFAP4, transforming growth factor-β1 (TGF-β1), cardiac ultrasound indexes, body mass index (BMI) and major cardio-cerebral vascular events were compared between the two groups. The receiver operating characteristic (ROC) curve was drawn to analyze the predictive value of MFAP4 for recurrence of AF after RFCA. Results: The levels of MFAP4, TGF-β1, left atrial diameter (LAD) and BMI in the recurrent group were higher than those in the non-recurrent group (P < 0.05). The left ventricular ejection fraction (LVEF) in the recurrent group was lower than that in the non-recurrent group (P < 0.05). The levels of MFAP4, TGF-β1 and LAD in the patients of recurrent paroxysmal AF and persistent AF after RFCA were higher than those in the respective non-recurrent patients (P < 0.05). MFAP4 was positively correlated with TGF - β 1 and LAD (P < 0.05). Logistic regression analysis showed that MFAP4, TGF-β1, and LAD were independent risk factors for recurrence of AF after RFCA. The ROC curve analysis showed that the area under the ROC curve of MFAP4 for predicting recurrence of AF after RFCA was 0.888 (P = 0.000), and the optimal cut-off value was 19.295ng/ml, with a sensitivity of 77.3% and a specificity of 77.2%. The incidence of readmission and total adverse events in recurrence group was significantly higher than that in non-recurrence group (P < 0.05). Conclusions: MFAP4 was significantly increased in patients with recurrence after RFCA of AF, which was one of the independent risk factors for recurrence after RFCA of AF, and had certain clinical application value.
推荐文章
An experimental study of interaction between pure water and alkaline feldspar at high temperatures a
Alkaline feldspar
Autoclave
High-temperature and high-pressure experiments
After Effects制作微课方法初探
微课
教学
After Effects
Trace element partitioning between amphibole and hydrous silicate glasses at 0.6–2.6 GPa
Amphibole
Silicate glass
Trace elements
Partition coefficients
Lattice strain model
探索 After Effects 在动画专业制作中的应用
After Effects(AE)
动画制作
功能应用
动画效果
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 The correlation between MFAP4 and recurrence and clinical outcome of atrial fibrillation after radiofrequency catheter ablation
来源期刊 海南医科大学学报(英文版) 学科
关键词
年,卷(期) 2021,(15) 所属期刊栏目 Original article
研究方向 页码范围 15-19
页数 5页 分类号
字数 语种 英文
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (31)
共引文献  (0)
参考文献  (12)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
1975(1)
  • 参考文献(0)
  • 二级参考文献(1)
1985(1)
  • 参考文献(0)
  • 二级参考文献(1)
1988(1)
  • 参考文献(0)
  • 二级参考文献(1)
1992(1)
  • 参考文献(0)
  • 二级参考文献(1)
1999(1)
  • 参考文献(0)
  • 二级参考文献(1)
2000(1)
  • 参考文献(1)
  • 二级参考文献(0)
2004(1)
  • 参考文献(0)
  • 二级参考文献(1)
2007(1)
  • 参考文献(0)
  • 二级参考文献(1)
2009(1)
  • 参考文献(0)
  • 二级参考文献(1)
2010(1)
  • 参考文献(0)
  • 二级参考文献(1)
2011(1)
  • 参考文献(0)
  • 二级参考文献(1)
2012(2)
  • 参考文献(0)
  • 二级参考文献(2)
2013(2)
  • 参考文献(1)
  • 二级参考文献(1)
2014(3)
  • 参考文献(0)
  • 二级参考文献(3)
2015(3)
  • 参考文献(1)
  • 二级参考文献(2)
2016(5)
  • 参考文献(1)
  • 二级参考文献(4)
2017(6)
  • 参考文献(1)
  • 二级参考文献(5)
2018(7)
  • 参考文献(4)
  • 二级参考文献(3)
2019(3)
  • 参考文献(2)
  • 二级参考文献(1)
2020(1)
  • 参考文献(1)
  • 二级参考文献(0)
2021(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
海南医科大学学报(英文版)
半月刊
1007-1237
海南省海口市学院路3号
eng
出版文献量(篇)
3478
总下载数(次)
0
总被引数(次)
315
  • 期刊分类
  • 期刊(年)
  • 期刊(期)
  • 期刊推荐
论文1v1指导