基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Purpose: To generate parametric images of tumor hypoxia in a tumor-bearing rat model using voxel-based compartmental analysis of dynamic fluorine-18 labeled misonidazole (18F-FMISO) microPET? images, and to compare the parametric images thus derived with static “late” 18F-FMISO microPET? images for the detection of tumor hypoxia. Materials and Methods: Nude rats bearing HT-29 colorectal carcinoma xenografts (≈1.5 - 2 cm in diameter) in the right hind limb were positioned in a custom-fabricated, animal-specific foam mold. Animals were injected via the tail vein with ≈55.5 MBq 18F-FMISO and continuously imaged for either 60 or 120 minutes, with additional late static images up to 3 hour post-injection. The raw list-mode data was reconstructed into 37 - 64 frames with earlier frames of shorter time durations (12 - 15 seconds) and later frames of longer durations (up to 300 seconds). Time activity curves (TACs) were generated over regions encompassing the tumor as well as an artery, the latter for use as an input function. A beta version of a compartmental modeling package (BioGuide?, Philips Healthcare) was used to generate parametric images of k3 and Ki, rate constants of entrapment and flux of 18F-FMISO, respectively. Results: Data for 7 HT-29 tumor xenografts were presented, 6 of which yielded clear areas of tumor hypoxia as defined by Ki/k3 maps. Importantly, intratumoral foci with high 18F-FMISO uptakes on the late images did not always exhibit high Ki/k3 values and may there- fore represent false-positives for radiobiologically significant hypoxia. Conclusions: This study attempts to quantify tumor hypoxia using compartmental analysis of dynamic 18F-FMISO PET images in rodent xenograft tumor models. The results demonstrate feasibility of the approach in small-animal imaging studies, and provide evidence for the possible unreliability of late-time static imaging of 18F-FMISO PET in identifying tumor hypoxia.
推荐文章
SUP-13配合比设计中若干问题的探讨
SUP-13
配合比
设计方法
弹簧钢SUP9D超声探伤缺陷分析
SUP9D弹簧钢
超声探伤
夹杂物
中间包
浅析sup改性沥青混凝土配合比设计要点
SBS改性沥青
混凝土
配合比设计
浅析
浅析sup改性沥青混凝土配合比设计要点
SBS改性沥青
配合比设计
设计要点
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Hypoxia Imaging of Rodent Xenografts with <sup>18</sup>F-Fluoromisonidazole: Comparison of Dynamic and Static PET Imaging
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 TUMOR HYPOXIA Dynamic image COMPARTMENTAL Modeling 18F-FMISO PET
年,卷(期) 2012,(3) 所属期刊栏目
研究方向 页码范围 95-104
页数 10页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2012(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
TUMOR
HYPOXIA
Dynamic
image
COMPARTMENTAL
Modeling
18F-FMISO
PET
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导