Focusing on the phenomenon of gypsum rain while wet desulphurization(WFGD) were adopted in coal fired power plant without GGH, the paper studied and put forward the solutions : (1) desulfurization facilities related equipment modification;(2) optimal operation of existing desulfurization facilities.