· AIM: To compare the accuracy of IOPen rebound tonometer with Goldmann applanation tonometer (GAT) in individuals with low, normal and high intraocular pressure (IOP) and to evaluate the effect of central corneal thickness (CCT) on IOP measurements. ·METHODS: This cross-sectional study consisted of 159 participants. IOP of one eye of each subject was measured consecutively with IOPen and GAT. Then CCT was measured using an ultrasonic pachymeter. Based on GAT IOP readings, participants were divided into low, normal and high IOP groups. Correlation between tonometers and CCT was calculated by spearman’s correlation coefficient. Agreement between tonometers was evaluated using Bland-Altman method. ·RESULTS: Non-significant underestimation of IOP by IOPen was observed in low IOP group (Mean difference: 0.20mmHg; =0.454) and also in normal IOP group (Mean difference: 0.56mmHg; =0.065). However, IOPen significantly overestimated IOP in high IOP group (Mean difference: 1.06mmHg; =0.038). The 95% limits of agreement (LoA) width between IOPen and GAT IOPs were 7.84, 8.57 and 14.27mmHg in low, normal and high IOP groups, respectively. Low IOP group had thinner corneas compared to high IOP group ( =0.034). IOP measurements taken by IOPen were not influenced by CCT ( =0.099) while poor correlation between CCT and GAT was found (R =0.17, =0.032). Using receiver operating characteristic (ROC) curve, cutoff value of 18.75mmHg was determined for IOPen with sensitivity of 98.1 and specificity of 97.2%. ·CONCLUSION: Accuracy of IOPen is comparable to GAT in patients with low or normal IOP but IOPen overestimates IOP at high IOP levels. CCT does not affect IOP readings with IOPen.
推荐文章
Goldmann压平眼压计与非接触式眼压计测量眼压的对比研究
Goldmann压平眼压计
非接触眼压计
眼内压
Goldmann眼压计与非接触眼压计测量青光眼患者眼压的对比分析
非接触式眼压计
Goldmann压平眼压计
青光眼
眼反应分析仪与Goldmann压平眼压计测量眼压的比较
眼内压
中央角膜厚度
Goldmann眼压计
ORA
角膜厚度对三种不同眼压计测量的影响
眼压测量
Goldmann
Schiotz
非接触眼压计
角膜厚度测量法
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Comparison of IOPen rebound tonometer with Goldmann applanation tonometer at different IOP levels
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 REBOUND TONOMETRY IOPen GOLDMANN applanation TONOMETRY INTRAOCULAR pressure
年,卷(期) 2013,(5) 所属期刊栏目
研究方向 页码范围 636-639
页数 4页 分类号 R77
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2013(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
REBOUND
TONOMETRY
IOPen
GOLDMANN
applanation
TONOMETRY
INTRAOCULAR
pressure
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
总被引数(次)
0
论文1v1指导