基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
· AIM: To assess the refractive outcome of clear lensectomy combined with piggyback intraocular lens implantation in highly hyperopic patients. ·METHODS: This case review included 19 eyes of 10 patients with high hyperopia and axial length less than 21mm. Intraocular lens power was calculated for emmetropia using the Holladay II formula in 17 eyes, and SRK/T formula in 2 eyes following clear lens extraction and piggyback intraocular lens implantation. Patients were examined periodically over 24 months for visual acuity and spherical equivalent (SE). ·RESULTS: The mean postoperative SE at 24 months was 0.20 ±1.39D (range, -3.00 to 2.50D), better than preoperative 9.81 ±2.62D (range, +6.00 to +14.50D) ( 【 0.001). Five eyes had SE within ±0.5D of emmetropia and 11 eyes within ±1.00D at postoperative 24 months. The mean postoperative uncorrected visual acuity (UCVA) at 24 months was 0.60 ±0.36, significantly improved compared to preoperative 1.39±0.33 ( 【0.001). The mean best -corrected visual acuity (BCVA) at 24 months was 0.49 ±0.35, not statistically different compared to preoperative 0.38±0.30 ( =0.34). Twelve eyes maintained and 1 gained 1 or more Snellen line of BCVA, 4 eyes lost 1 line, and 2 eyes lost 2 lines at 24 postoperative months. Twelve eyes best -corrected near visual acuity (BCNVA) achieved J1 at postoperative 24 months compared to preoperative 7 eyes and the other 7 eyes better than J3. ·CONCLUSION:Clearlensextractioncombinedpiggyback intraocular lens implantation appears to be an effective procedure to correct high hyperopia but mild overcorrection and intralenticular opacification may require secondary procedure.
推荐文章
The use of in-situ cosmogenic 21Ne in studies on long-term landscape development
Cosmogenic nuclides
21Ne
Long timescale
Landscape evolution
C-lens准直特性分析
C-lens
高斯光束
光纤准直器
工作距离
A re-assessment of nickel-doping method in iron isotope analysis on rock samples using multi-collect
Fe isotope
Ni-doping
Stable isotope
Precision and accuracy
Mass bias correction
Pseudo-high mass resolution
Thermodynamic properties of San Carlos olivine at high temperature and high pressure
San Carlos olivine
Thermodynamic property
Thermal expansion
Heat capacity
Temperature gradient
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Long-term results of clear lens extraction combined with piggyback intraocular lens implantation to correct high hyperopia
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 PIGGYBACK intraocularlens highhyperopia
年,卷(期) 2013,(5) 所属期刊栏目
研究方向 页码范围 649-654
页数 6页 分类号 R77
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2013(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
PIGGYBACK
intraocularlens
highhyperopia
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
总被引数(次)
0
论文1v1指导