AIM: To evaluate the efficacy and safety of active removal of silicone oil with low and high viscosity through a 23-gauge transconjunctival cannula using an external vacuum pump.METHODS: This study was conducted as a prospective, interventional case series. A total of 22 eyes of 21 patients [1000 centistokes(c St): 17 eyes, 5700 c St:5 eyes] were included in this study. All patients underwent active silicone oil removal via the entire lumen of a 23-gauge microcannula with suction pressure of a650-700 mm Hg vacuum using an external vacuum pump. A tubing adaptor from the Total Plus Pak誖(Alcon,Fort Worth, USA) was used to join the microcannula and silicone vacuum tube connected to an external vacuum pump. Main outcome measures were mean removal time,changes of intraocular pressure(IOP) and visual acuity,and intraoperative and postoperative complications.RESULTS: Mean removal time(min) was 1.49±0.43 for1000 c St and 7. 12 ± 1. 27 for 5700 c St. The IOP was18.57±7.48 mm Hg at baseline, 11.68 ±4.55 mm Hg at day1 postoperatively(P 【0.001), and 15.95±4.92, 16.82±3.81,17.41 ±3.50, and 17.09 ±3.01 mm Hg after one week, one month, three months, and six months, respectively. All patients showed improved or stabilized visual acuity.There was no occurrence of intraoperative or postoperative complications during the follow up period.CONCLUSION: This technique for active removal of silicone oil through a 23-gauge cannula using an external vacuum pump is fast, effective, and safe as well as economical for silicone oil with both low and high viscosity in all eyes with pseudophakia, aphakia, or phakia.
推荐文章
Origin and genetic family of Huhehu oil in the Hailar Basin, northeast China
Hailar Basin
Huhehu Sag
Biomarkers
Chemometrics
Oil–oil and oil–source rock correlations
Oil geochemistry derived from the Qinjiatun–Qikeshu oilfields: insight from light hydrocarbons
Light hydrocarbons
Crude oil
Lishu Fault Depression
Geochemistry characteristic
基于BlueCore2-External蓝牙芯片的监控系统设计
蓝牙
BlueCore2-External芯片
监控系统
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Efficacy and safety of active silicone oil removal through a 23-gauge transconjunctival cannula using an external vacuum pump
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 ACTIVE removal EXTERNAL vacuum PUMP SILICONE oil
年,卷(期) 2015,(2) 所属期刊栏目
研究方向 页码范围 347-352
页数 6页 分类号 R779.6
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2015(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
ACTIVE
removal
EXTERNAL
vacuum
PUMP
SILICONE
oil
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
总被引数(次)
0
论文1v1指导