基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Background: There is a huge gap in the audiological care in Africa by comparison with Western countries. Its main reason is the prohibitive cost of the medical devices used to screen or diagnose patients. A Cameroonian team tackled this problem by developing a medical device (SON’OR©) which integrates a new instrumentation amplifier structure dedicated to perform otoacoustic emissions (OAE) and brainstem evoked response audiometry (BERA). The major technical challenges to perform OAE and BERA are the synchronization and the amplification of signals of very low amplitude. In this work, we emphasize on the general criteria necessary and indispensable to achieve an optimal amplification. The application of a novel instrumentation amplifier structure characterized by its optimized noise factor in the case of BERA and OEA emissions provides simulations and experimental results fully in line with forecasts. The design of SON’OR©is based on general techniques of electronic instrumentation to which we associated the new instrumentation amplifier structure. Objective: To report the clinical evaluation of SON’OR©as a screening and diagnostic tool. Methods: We conducted a cross sectional comparative study in Centre Hospitalier d’Essos in Yaoundé. We tested SON’OR©on two sets of subjects, one for OAE with OTODYNAMICS Echoport ILO 292-II as gold standard and the other for BERA with NEUROSOFT NEURO AUDIO©as gold standard. Each patient was tested with both devices and then we studied the inter device differences and calculated the sensitivity, specificity, positive predictive value and negative predictive value for each test. Results: We got 52 subjects for OEA and 51 for BERA testing. Sex ratio was 1 woman for 2 men in both groups. Mean age was 24.86(SD = 10.53) and 26.33 (10.55) for OAE and BERA groups respectively. SON’OR©had good performances, showing sensitivity of 92.85%/95%, specificity of 96.77%/90.47%, positive predictive value of 95.21%/93.44% and negative predictive value of
推荐文章
SUP-13配合比设计中若干问题的探讨
SUP-13
配合比
设计方法
弹簧钢SUP9D超声探伤缺陷分析
SUP9D弹簧钢
超声探伤
夹杂物
中间包
浅析sup改性沥青混凝土配合比设计要点
SBS改性沥青
混凝土
配合比设计
浅析
浅析sup改性沥青混凝土配合比设计要点
SBS改性沥青
配合比设计
设计要点
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Evaluation of SON’OR<sup>©</sup>, a Medical Device for Provoked Otoacoustic Emissions and Brainstem Evoked Response Audiometry Made in Cameroon
来源期刊 生物医学工程(英文) 学科 医学
关键词 SON’OR? BRAINSTEM EVOKED Response AUDIOMETRY Otoacoustic Emissions Cameroon NEONATAL Hearing Screening
年,卷(期) 2017,(8) 所属期刊栏目
研究方向 页码范围 376-389
页数 14页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2017(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
SON’OR?
BRAINSTEM
EVOKED
Response
AUDIOMETRY
Otoacoustic
Emissions
Cameroon
NEONATAL
Hearing
Screening
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
生物医学工程(英文)
月刊
1937-6871
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
252
总下载数(次)
1
总被引数(次)
0
论文1v1指导