基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM To investigate technical feasibility, outcomes and adverse events of the lumen-apposing metal stent(LAMS) for benign gastrointestinal(GI) tract strictures.METHODS Between July 2015 and January 2017, patients undergoing treatment by LAMS for benign GI strictures at three tertiary referral centers were included in this study. Primary outcomes included technical success, shortterm clinical success, long-term clinical success, and adverse events. Short-term clinical success was defined as symptom resolution at 30 d after stent placement. Longterm clinical success was defined by symptom resolution at 60 d in patients who continued to have indwelling stent, or continued symptom resolution at 30 d after elective stent removal.RESULTS A total of 21 patients(mean age 62.6 years, 47.6% males) underwent placement of LAMS for benign GI strictures. A 15 mm × 10 mm LAMS was placed in 16 patients, a 10 mm × 10 mm LAMS was placed in 2 patients, and a 16 mm × 30 mm LAMS was placed in 3 patients. Technical success was obtained in all cases. Short-term clinical success was achieved in 19 out of 21 cases(90.5%), and long-term clinical success was achieved in 12 out of 18(66.7%). Mean(range) stent indwell time was 107.2(28-370) d. After a mean(range) dwell time of 104.3(28-306) d, 9 LAMSs were removed due to the following complications: ulceration at stent site(n = 1), angulation(n = 2), migration(n = 4) and stricture overgrowth(n = 2). Migration occurred in 4 cases(19.0%), and it was associated with stricture resolution in one case. Median(range) follow-up period was 119(31-422) d. CONCLUSION Utilization of LAMS for benign strictures has shown to be technically feasible and safe, but adverse events highlight the need for further study of its indications.
推荐文章
An experimental study on metal precipitation driven by fluid mixing: implications for genesis of car
Metal precipitation
Fluid mixing
Sulfur species
MVT lead–zinc ore deposits
Carbonate-hosted
lead–zinc deposits
HU-METAL法成型钢管的残余应力分析
直缝焊钢管
残余应力
成型
原理
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Lumen-apposing metal stents for benign gastrointestinal tract strictures: An international multicenter experience
来源期刊 世界胃肠内镜杂志:英文版(电子版) 学科 医学
关键词
年,卷(期) 2017,(12) 所属期刊栏目
研究方向 页码范围 571-578
页数 8页 分类号 R57
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2017(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
引文网络交叉学科
相关学者/机构
期刊影响力
世界胃肠内镜杂志:英文版(电子版)
月刊
1948-5190
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
557
总下载数(次)
0
总被引数(次)
0