基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Purpose: Dosimetric study to evaluate impact of “beam” reduction in AVM radiosurgery on normal brain dose parameters and it’s clinical implications. Materials and Methods: Five small volume AVMs (nidus volume 0.31 - 1.94 cc) planned for single fraction SRS with robotic radiosurgery system. Planning scans done with CT scan brain, CT & MR angiography, then nidus volume and organ at risk (OARs) were contoured. Planning was done with multiplan planning system. Plan evaluated as per Flickenger model parameters of 12 Gy nomal brain vol & marginal dose. 7.5 mm and 10 mm cons used, optimization done with seqential algorithm. 20 Gy was prescribed to isodose with appropriate nidus coverage (>98%). Total beams of five plans were 85 - 250, monitor unit 17,259 - 24,602 MU. 12 Gy normal brain volume is 0.9 - 7.6 cc. Then beam reduction is done by reducing beams with minimum MU in steps of 50, 100, 150, 200, 250 MU and after beam reduction, re-optimization done. Prescription isodose was changed to keep the nidus coverage > 98%. Impacts of beam reduction on 12 Gy normal brain vol and conformity/homogeniety index were analyzed. Results: Optimal plans of five patients with 20 Gy prescribed to 88% - 90% isodose, nidus coverage more than 98%. In dosimetric parameters, mean CI was 1.36 - 1.51, nCI 1.41 - 1.51, HI 1.1 - 1.4 and mean 12 Gy normal brain volume 0.17, 1.44, 5.3, 5.5 and 7.6cc respectively. After beam reduction of less than 50 MU contribution (in case#1), prescibing at suitable isodose (85%) beam reduces to 79 and 12 Gy volume marginally increases to 26.4 cc. Beam reduction of less than 100 MU reduces to 53 - 92 beamlets. Reduction of beams with less than 150 MU contribution did not significantly change the 12Gy normal brain volume. However, reduction of beamlets with more than 200 MU, 250 MU, 300 MU, 450 MU and 550 MU significantly affects the 12 Gy normal brain volume. Prescription-isodose modified from 83% to 50% to have >98% coverage. CI and HI increased from 1.36 - 1.51 to 2.51 - 2.63 and 1.1 - 1.4 to 1.52 - 1.5
推荐文章
浅谈S12 STP计费
S12 STP计费系统 实现方法 应用
微量元素钴对抗生素AVM生产的影响
菌丝体
阿维菌素
微量元素
一种基于Normal矩阵的时间序列聚类方法
时间序列聚类
社团结构
复杂网络
Normal矩阵
相似度
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Arteriovenous Malformation (AVM) Treated with Robotic Radiosurgery: Impact of Beam Reduction in 12 Gy Normal Brain Volume and It’s Clinical Implication
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 AVM ROBOTIC RADIOSURGERY CK-Cyberknife 12 GY Volume BEAM REDUCTION
年,卷(期) 2019,(3) 所属期刊栏目
研究方向 页码范围 131-140
页数 10页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
AVM
ROBOTIC
RADIOSURGERY
CK-Cyberknife
12
GY
Volume
BEAM
REDUCTION
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导