基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Background and Objective: Nowadays, Computer Tomography is one of the best radiological imaging technics which can give right diagnostic information, among the detection of multiphasic adenomas, the detection of cardiac, cerebral and vascular abnormalities. Although these good qualities, this technic is too radiant for the patient. In this paper, we based on the irradiation doses delivered from the current protocols to find a practical method of their optimization during the pediatric cranial scan. Materials and Methods: This work relies on a collection of data from patients in the hospitals, so that analyze them, give the conclusions and, propose an optimal practical method to decrease the irradiation doses. To collect data, we performed a prospective study of seventeen months (from December 2017 to May 2019) carried out simultaneously in three hospitals of the city: The Centre Medical la Cathédrale (H1), the Yaoundé Central Hospital (H2) and the Yaoundé Gyneaco-Obstetric and pediatric hospital (H3). This study included a total of 192 cases of cerebral trauma, of which 11 cases excluded for incomplete information. The dosimetry quality control (CTDIvol) using the PMMA phantoms of 16 cm and 32 cm fulfilled. The scanographic parameters of the patient acquisition protocol were recorded and analyzed. Some of those parameters were modified and entered the CT with the help of a biomedical engineer to reduce the delivered dose. The relationship between CTDIvol and kV is statistically significant (p Results: Among patients, 172 are boys, and the remaining 9 are girls all were in the 0 to 15 age group. CTDIvol values varied from 34.2 mGy to 107.8 mGy and PDLs from 107.8 mGy.cm to 2214.5 mGy.cm in H1. In H2, CTDIvol varied from 5.8 mGy to 44 mGy and PDLs from 91.4 mGy.cm to 665.5 mGy.cm. CTDIvol varied between 9.34 mGy to 92.81 mGy and PDLs from 162.38 mGy.cm to 2713.67 mGy.cm in H3. All values are taken at 75th percentile, with or without contrast injection. Conclusion: The implementation of the optimization of protoc
推荐文章
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Dose Optimization in Computer Tomography Pediatric Cranial Scans
来源期刊 放射学期刊(英文) 学科 医学
关键词 COMPUTED TOMOGRAPHY DOSE Optimization PEDIATRIC CRANIAL Scans PROTOCOL
年,卷(期) 2019,(4) 所属期刊栏目
研究方向 页码范围 181-193
页数 13页 分类号 R81
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
COMPUTED
TOMOGRAPHY
DOSE
Optimization
PEDIATRIC
CRANIAL
Scans
PROTOCOL
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
放射学期刊(英文)
季刊
2164-3024
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
256
总下载数(次)
0
总被引数(次)
0
论文1v1指导