基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
In this paper, we present the results of the evaluation of three low-cost laser sensor</span><span style="font-family:Verdana;">s</span><span style="font-family:""><span style="font-family:Verdana;"> and comparison with the standard device Metone Aerocet 531s which is capable of counting dust particles as small as 0.3 μm. The sensors used in this study are PMS5003 (Plantower), SPS30 (Sesirion), SM-UART-04L (Amphenol). During the measurement, the overall trend of the outputs from the sensors was similar to that of the Aerocet 531s. The PMS5003 sensor has a relatively small standard error in the all particle measurement ranges (<15 μg/m</span><sup><span style="font-family:Verdana;">3</span></sup><span style="font-family:Verdana;"> in the low particle concentration range). All sensors have a high linearity compared to data from standard equipment, PMS5003: PM1.0 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.89;PM2.5 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.95;PM10 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.87;SPS30 PM2.5 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.95 and PM10 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.99;SM-UART-04L PM1.0 R</span><sup><span style="font-family:Verdana;">2</span></sup><span style="font-family:Verdana;"> = 0.98. Three main sensor calibration methods (single-point calibration, two-point calibration and multi-point curve correction) with implementation steps for each method as well as their practical applications in calibrating low-cost air quality sensors according to standard measuring equipment are also detailed illustrated.
推荐文章
Using Geomechanical Method to Predict Tectonic Fractures in Low-Permeability Sandstone Reservoirs
Low-permeability sandstone reservoir
Fracture parameters
Geomechanical method
Assessment of groundwater quality with special emphasis on nitrate contamination in parts of Gautam
Leachate
Hydrochemical parameters
Piper plot
Ternary and Durov's diagram
Spatial variation
基于Internet的数字示波器e-Calibration技术研究
远程校准
数字存储示波器
互联网
Application ontology构建及SPARQL查询研究
本体
手机应用
简单协议和RDF查询语言
查询
本体描述语言
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Evaluating Low-Cost Commercially Available Sensors for Air Quality Monitoring and Application of Sensor Calibration Methods for Improving Accuracy
来源期刊 大气污染开放期刊(英文) 学科 工学
关键词 Air Quality Sensors Sensor Calibration Air Pollution Fine Particle Laser Particle Sensor PM1.0 PM2.5 PM10
年,卷(期) 2021,(1) 所属期刊栏目
研究方向 页码范围 1-17
页数 17页 分类号 TP2
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2021(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Air
Quality
Sensors
Sensor
Calibration
Air
Pollution
Fine
Particle
Laser
Particle
Sensor
PM1.0
PM2.5
PM10
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
大气污染开放期刊(英文)
季刊
2169-2653
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
26
总下载数(次)
0
总被引数(次)
0
论文1v1指导