基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM:To determine the influence of anthropomorphic parameters on the relationship between patient centering,mean computed tomography(CT) numbers and quantitative image noise in abdominal CT.METHODS:Our Institutional Review Board approved study included 395 patients(age range 21-108,years;male:female = 195:200) who underwent contrast-enhanced abdominal CT on a 16-section multi-detector row scanner(GE LightSpeed 16).Patient centering in the gantry isocenter was measured from the lateral localizer radiograph(off center S = patient off centered superior to isocenter;off center I = patient off centered inferior to isocenter).Mean CT numbers(Hounsfield Units:HU) and noise(standard deviation of CT numbers:SD) were measured in the anterior(aHU,aSD) and posterior(pHU,pSD) abdominal wall subcutaneous fat and liver parenchyma(LivHU,LivSD) at the level of the porta hepatis.Patients’ age,gender,weight,body mass index and maximal anteroposterior diameter were recorded.The data were analyzed using linear regression analysis.RESULTS:Most patients(81%;320/395) were not correctly centered in the gantry isocenter for abdominal CT scanning.Mean CT numbers in the abdominal wall increased significantly with an increase in the offcentering distance,regardless of the direction of the off-center(P 【 0.05).There was a substantial increase in pSD(P = 0.01) and LivSD(P = 0.017) with off-centering.Change in mean CT numbers and image noise along the off-center distance was influenced by the patient size(P 【 0.01).CONCLUSION:Inappropriate patient centering for CT scanning adversely affects the reliability of mean CT numbers and image noise.
推荐文章
The partitioning patterns of nutrients between pods and seeds of Zanthoxylum fruits impacted by envi
Partitioning pattern
Nutritional quality
C:N ratio
Zanthoxylum fruits
Mean annual temperature
Mean annual precipitation
The influence of climate and topography on chemical weathering of granitic regoliths in the monsoon
Granitic regolith
Chemical weathering
Supply-limited weathering
Kinetic-limited weathering
An experimental study of interaction between pure water and alkaline feldspar at high temperatures a
Alkaline feldspar
Autoclave
High-temperature and high-pressure experiments
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Relationship between patient centering,mean computed tomography numbers and noise in abdominal computed tomography:Influence of anthropomorphic parameters
来源期刊 世界放射学杂志:英文版(电子版) 学科 医学
关键词 Automatic exposure control COMPUTED tomography radiation DOSE reduction Patient offcentering Tube current modulation
年,卷(期) 2012,(3) 所属期刊栏目
研究方向 页码范围 102-108
页数 7页 分类号 R816.5
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2012(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Automatic
exposure
control
COMPUTED
tomography
radiation
DOSE
reduction
Patient
offcentering
Tube
current
modulation
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界放射学杂志:英文版(电子版)
月刊
1949-8470
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
785
总下载数(次)
1
总被引数(次)
0
论文1v1指导