基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Purpose: To prospectively analyze the inter-fractional motion of the prostate in patients with prostate cancer treated with intensity-modulated radiation therapy (IMRT) using image-guided radiotherapy (IGRT) with daily cone-beam computed tomography (CBCT) as part of a rescan protocol for large offset, and to evaluate the efficacy of our protocol. Materials and Methods: Eligible patients were treated with the following protocol: 1) magnesium oxide and dimethylpolysiloxane were administered to ensure that patients had regular bowel movements;2) the patients were instructed to have an appropriately distended bladder during the planning CT and daily irradiation;3) the daily CBCT image was fused with the planning CT image using the prostate outline;and 4) if large offset was recognized, a rescan CBCT image was obtained after appropriate countermeasures, such as the discharge of gas and defecation, and re-registration was performed. Three shifts for the inter-fractional motion of the prostate were analyzed, in the fractions which needed the CBCT rescan;the displacement data after the final rescan were used. Results: Sixty-one patients were eligible, and a total of 2302 fractions were available for the analysis. Rescans of the CBCT for large offset were performed in 113 (5%) of the 2302 fractions. After the first rescan, the large offset was resolved in 106 (94%) of the 113 fractions. Excessive rectal gas was the reason for the large offset in 94 (83%) of the 113 fractions. The total mean and standard deviation of the inter-fractional motion of the prostate in the AP, LR, and SI directions were 1.1 ± 2.4, -0.1 ± 2.3, and 0.7 ± 3.0 mm, respectively. Conclusion: Large offset was recognized in 5% of all fractions. Daily CBCT with our rescan protocol could resolve the large offset, which was mainly caused by excessive rectal gas, and it may therefore be promising to reduce the inter-fractional motion of the prostate.
推荐文章
带有Fractional Brownian Motion和Markovian调制的随机资产积累的最优逼近控制
Fractional Brownian Motion
Markov Process
最优逼近控制
最大值原理
Ekeland变分
Ito's公式
小议课前 Daily report
Daily report
实效性
多样化
合理评价
小议课前Daily report
Daily report
实效性
多样化
合理评价
一种基于区间Bézier曲线的Offset逼近曲线
区间Bézier曲线
Offset曲线
拟合
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Efficacy of Daily Cone-Beam Computed Tomography as Part of a Rescan Protocol for Large Offset to Reduce the Inter-Fractional Motion of the Prostate
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 INTENSITY-MODULATED Radiotherapy PROSTATE Cancer DAILY Cone Beam Computed Tomography Inter-Fractional MOTION
年,卷(期) 2014,(4) 所属期刊栏目
研究方向 页码范围 193-200
页数 8页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2014(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
INTENSITY-MODULATED
Radiotherapy
PROSTATE
Cancer
DAILY
Cone
Beam
Computed
Tomography
Inter-Fractional
MOTION
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导