基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
AIM : To evaluate the prediction error in intraocular lens(IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position(ELP).METHODS: Retrospective study including a total of 25 eyes of 13 patients(age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL(Oculentis Gmb H, Germany). In all cases, an adjusted IOL power(P IOLadj) was calculated based on Gaussian optics using a variable keratometric index value(n kadj) for the estimation of the corneal power(P kadj) and on a new value for ELP(ELP adj) obtained by multiple regression analysis.This P IOLadj was compared with the IOL power implanted(P IOLReal) and the value proposed by three conventional formulas(Haigis, Hoffer Q and Holladay Ⅰ).RESULTS: P IOLReal was not significantly different than P IOLadj and Holladay IOL power(P 】0.05). In the Bland and Altman analysis, P IOLadj showed lower mean difference(-0.07 D) and limits of agreement(of 1.47 and-1.61 D)when compared to P IOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELP adj was significantly lower than ELP calculated with other conventional formulas(P 【0.01) and was found to be dependent on axial length, anterior chamber depth and P kadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing thekeratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.
推荐文章
C-lens准直特性分析
C-lens
高斯光束
光纤准直器
工作距离
Estimation of soil organic carbon storage and its fractions in a small karst watershed
Bare rock rate
Estimation method
soil organic carbon storage
Small watershed
Karst
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens
来源期刊 国际眼科杂志:英文版 学科 医学
关键词 Mplus multifocalintraocularlens KERATOMETRY EFFECTIVE LENS POSITION INTRAOCULAR LENS POWER
年,卷(期) 2015,(3) 所属期刊栏目
研究方向 页码范围 501-507
页数 7页 分类号 R772.2
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (35)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2015(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Mplus
multifocalintraocularlens
KERATOMETRY
EFFECTIVE
LENS
POSITION
INTRAOCULAR
LENS
POWER
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
国际眼科杂志:英文版
月刊
2222-3959
西安市友谊东路269号
出版文献量(篇)
2720
总下载数(次)
2
总被引数(次)
0
论文1v1指导