基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Between April 2013 and October 2015, 6 patients developed periampullary duodenal or jejunal/biliary leaks after major abdominal surgery. In all patients, percutaneous drainage of the collection or re-operation with primary surgical repair was attempted at first but failed. A fully covered enteral metal stent was placed in all patients to seal the leak. Subsequently, we cannulated the common bile duct and, in some cases, and the main pancreatic duct inserting hydrophilic guidewires through the stent after dilating the stent mesh with a dilatation balloon or breaking the meshes with Argon Plasma Beam. Finally, we inserted a fully covered biliary metal stent to drain the bile into the lumen of the enteral stent. In cases of normal proximal upper gastrointestinal anatomy, a pancreatic plastic stent was also inserted. Oral food intake was initiated when the abdominal drain outflow stopped completely. Stent removal was scheduled four to eight weeks later after a CT scan to confirm the complete healing of the fistula and the absence of any perilesional residual fluid collection. The leak resolved in five patients. One patient died two days after the procedure due to severe, pre-existing,sepsis. The stents were removed endoscopically in four weeks in four patients. In one patient we experienced stent migration causing small bowel obstruction. In this case, the stents were removed surgically. Four patients are still alive today. They are still under follow-up and doing well. Bilio-enteral fully covered metal stenting with or without pancreatic stenting was feasible, safe and effective in treating postoperative enteral leaks near the biliopancreatic orifice in our small series. This minimally invasive procedure can be implemented in selected patients as a rescue procedure to repair these challenging leaks.
推荐文章
Rapid estimation of soil heavy metal nickel content based on optimized screening of near-infrared sp
Heavy metal
Band extraction
Partial least squares regression
Extreme learning machine
Near infrared spectroscopy
An experimental study on metal precipitation driven by fluid mixing: implications for genesis of car
Metal precipitation
Fluid mixing
Sulfur species
MVT lead–zinc ore deposits
Carbonate-hosted
lead–zinc deposits
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Endoscopic multiple metal stenting for the treatment of enteral leaks near the biliary orifice: A novel effective rescue procedure
来源期刊 世界胃肠内镜杂志:英文版(电子版) 学科 医学
关键词 ENDOSCOPIC retrograde PANCREATIC duct Fully covered metal STENT Duodenal LEAK Postoperative complications ENTERAL LEAK ENTERAL STENT BILIARY STENT PANCREATIC STENT
年,卷(期) 2016,(15) 所属期刊栏目
研究方向 页码范围 533-540
页数 8页 分类号 R
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2016(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
ENDOSCOPIC
retrograde
PANCREATIC
duct
Fully
covered
metal
STENT
Duodenal
LEAK
Postoperative
complications
ENTERAL
LEAK
ENTERAL
STENT
BILIARY
STENT
PANCREATIC
STENT
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
世界胃肠内镜杂志:英文版(电子版)
月刊
1948-5190
北京市朝阳区东四环中路62号楼远洋国际中
出版文献量(篇)
557
总下载数(次)
0
总被引数(次)
0
  • 期刊分类
  • 期刊(年)
  • 期刊(期)
  • 期刊推荐
论文1v1指导