基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Purpose: To compare the impact of induced astigmatism with four different types of multifocal intraocular lenses (MIOLs). Method: Prospective, comparative, interventional, mono-centered study, including 80 eyes of patients with implantation of four different MIOLs: AcrySof ReSTOR +2.5 D (20 eyes), AcrySof ReSTOR +3.0 D (20 eyes), AcrySof Panoptix (20 eyes) (Alcon Laboratories, Inc., Fort Worth, TX, USA), and Tecnis Symfony ZRX00 (Abbott Medical Optics, Santa Ana, USA) (20 eyes). Patients were followed up for 3 months after surgery. Major parameters were uncorrected (UDVA) and corrected (CDVA) distance visual acuity, subjective refraction and patient satisfaction. Results: Differences between IOLs with regard to the impact of the cylinder sign and axis on visual acuity and patient satisfaction were not significant. With mild added negative cylinder, AcrySof ReSTOR +2.5 D and Tecnis Symfony IOLs maintained the baseline visual acuity, while it was mildly reduced with AcrySof ReSTOR +3.0 D and Panoptix IOLs. With moderate induced cylinder, the Tecnis Symfony IOL maintained good visual acuity and patient associated satisfaction. Panoptix IOL was the IOL most affected by the induced astigmatism with regard to dissatisfaction and visual acuity. The highest tolerance to the astigmatic distortion and blurriness induced with a -1.50 D cylinder was obtained with the Tecnis Symfony IOL. Tecnis Symfony IOL showed less dissatisfaction and less reduction of visual acuity than the other MIOLs. Conclusion: Simulated residual cylinders after the implantation of the Tecnis Symfony IOL up to 1.0 D have a very mild and not clinically relevant impact on visual acuity or patient satisfaction. The ERV IOL showed a better tolerance to unexpected postoperative residual errors than diffractive bifocal and trifocal IOLs.
推荐文章
基于Vision的果蝇复眼病变图像的处理
果蝇
机器视觉
Vision 8.5
图像处理
基于Range检验的AR(p)模型参数变点的在线监测
AR(p)模型
变点
在线监测
有效得分向量
DCE-MRI Extended tofts模型和Reference Region模型在肺部结节/肿块良恶性诊断中的应用价值
动态对比增强磁共振成像
肺结节/肿块
药代动力学模型
对比研究
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Residual Astigmatism Threshold and Patient Satisfaction with Bifocal, Trifocal and Extended Range of Vision Intraocular Lenses (IOLs)
来源期刊 眼科学期刊(英文) 学科 医学
关键词 MULTIFOCAL IOL ASTIGMATISM Tolerance Bifocal Trifocal Extended Range of VISION TECNIS Symfony Panoptix ACRYSOF RESTOR
年,卷(期) 2017,(1) 所属期刊栏目
研究方向 页码范围 1-7
页数 7页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2017(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
MULTIFOCAL
IOL
ASTIGMATISM
Tolerance
Bifocal
Trifocal
Extended
Range
of
VISION
TECNIS
Symfony
Panoptix
ACRYSOF
RESTOR
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
眼科学期刊(英文)
季刊
2165-7408
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
241
总下载数(次)
0
总被引数(次)
0
论文1v1指导