摘要:
The feasibility of a volumetric modulated arc therapy (VMAT) based coronal arc (cARC) technique for treating a single brain metastasis or lesion proximal to the brainstem or optic chiasm was evaluated. Coplanar (CP) and non-coplanar (NCP) treatment plans to an anthropomorphic head/neck phantom scanned head-first supine were compared to a cARC plan with the phantom rotated vertically. A set of planning target volumes (PTVs) were contoured centrally between the brainstem and optic chiasm (“Ant PTVs”) and posterior to brainstem (“Post PTVs”). Dosimetric indices such as conformity index (C.I.), gradient measure (G.M.), and dose volume histograms (DVHs) were compared for CP, NCP and cARC techniques. The TG101 guidelines for organs-at-risk (OARs), and 95% of PTV receiving at least 100% of the prescription dose (D95 = 100%) were used as plan objectives. Reductions in D50 and D30 to the brainstem of 85.1% ± 3.9% and 87.6% ± 3.2%, respectively were seen for “Post PTVs”, and 51.1% ± 17.8% and 85.6% ± 6.0% respectively for “Ant PTVs” using cARC versus CP (p ≤ 0.01). For chiasm, reductions of D50 and D30 were 61.7% ± 3.2% and 44.2% ± 8.9% for “Ant PTVs”, by 69.3% ± 8.0% and 74.3% ± 8.2% for “Post PTVs” (p ≤ 0.01). Comparing cARC to NCP led to similar dosimetric improvements. The conformity index (C.I.) was measured to be 1.101 ± 0.038, 1.088 ± 0.054, and 1.060 ± 0.040 for cARC, CP and NCP respectively (p ≤ 0.01). The overall GM in cm was 0.581 ± 0.097, 0.708 ± 0.064, and 0.476 ± 0.050 for cARC, CP and NCP respectively (p ≤ 0.01). The mean distance gradient fall-off (in cm) was 0.249 ± 0.038 (cARC), 0.749 ± 0.107 (CP), and 0.621 ± 0.068 (NCP) at the center slice in anterior-posterior direction of the target volume (p ≤ 0.01). The objective of this study is to compare the dosimetric indices of cARC with CP and NCP techniques. In conclusion, cARC can provide improved dosimetry as compared to CP and NCP for lesion proximal to the brainstem or optic chiasm.
推荐文章
ARC网格中间件的研究与实现
网格
网格中间件
G1obus
Information system
Grid manager
Geo Media到Arc GIS的数据转换方法
Geo Media
Arc GIS
数据格式转换
坐标变换
数据处理
ARC/INFO(R)接受Surfer图文数据的实现
ARC/INFO
Surfer
数据格式
数据转换
基于ARC/INFO的土地信息系统设计
ARC/INFO
土地信息系统
数据库
模块功能
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Dosimetric Advantages of Volumetric Modulated Arc Therapy Based Coronal Arc Delivery Technique in Brain Stereotactic Radiosurgery: A Feasibility Study
来源期刊 医学物理学、临床工程、放射肿瘤学(英文) 学科 医学
关键词 VMAT CORONAL ARC π-Geometry COPLANAR Non-Coplanar STEREOTACTIC RADIOSURGERY
年,卷(期) 2019,(2) 所属期刊栏目
研究方向 页码范围 80-94
页数 15页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2019(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
VMAT
CORONAL
ARC
π-Geometry
COPLANAR
Non-Coplanar
STEREOTACTIC
RADIOSURGERY
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
医学物理学、临床工程、放射肿瘤学(英文)
季刊
2168-5436
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
236
总下载数(次)
0
总被引数(次)
0
论文1v1指导