基本信息来源于合作网站,原文需代理用户跳转至来源网站获取       
摘要:
Background: A recent survey of in-hospital reprocessing in Tanzanian hospitals identified bag-valve masks (BVM) as a commonly reused single-use device. In low- and middle-income countries (LMIC), in-hospital reprocessing supports neonatal resuscitation strategies by helping to maintain adequate supplies of BVM. However, there is a need for device-specific protocols defining reprocessing procedures and inspection criteria to overcome variations in reprocessing practices between hospitals. The purposes of this study were: 1) to complete a comprehensive design review and identify challenges to reprocessing BVMs;and 2) to investigate three different residual bioburden analysis methods for assessing the efficacy of decontaminating a disposable BVM. Methods: New, unused bag-valve-masks were contaminated with Staphylococcus epidermidis and Artificial Mucus Soil to simulate the worst case soiling conditions. Devices underwent one of five disinfection protocols, including one currently used in a LMIC hospital. Three analytical (two quantitative and one qualitative) methods were selected to evaluate residual bioburden on the device following decontamination. Results: Of all protocols tested, only the positive control and the Soap and Bleach protocols met disinfection targets. Most cleaning outcomes were consistent from trial to trial for each protocol. However, cleaning outcomes varied greatly for the Alcohol Wipe protocol. For the residual bioburden analyses, the two quantitative methods produced similar results, but the qualitative measurement exhibited increased variability. Conclusion: While this study revealed positive disinfection outcomes for the Tanzanian hospital decontamination protocol, more studies are required to support these findings. Design features of the BVM mask presented challenges to cleaning and drying during different decontamination protocols, as seen in the variability in the Alcohol Wipe protocol performance. These findings support the case for a device-specific protocol for the BVM. Given proper
推荐文章
利用 UNICORN BAG 培养香菇菌种试验
透气膜
塑料袋
香菇
菌种
14位Single-slope ADC行为级建模与仿真
单斜模/数转换器
行为级建模
红外焦平面
Simulink
集成电路设计
功能仿真
基于改进的Single-pass算法的新闻热点的发现
新闻热点
话题发现
聚类算法
内容分析
关键词云
关键词热度
相关文献总数  
(/次)
(/年)
文献信息
篇名 Single-Use Bag Valve Masks: Evaluation of Device Design and Residual Bioburden Analytical Methods
来源期刊 生物医学工程(英文) 学科 医学
关键词 Reprocessing Low-Resource BAG VALVE Mask Single-Use Device Low-and Middle-Income Countries Newborn Resuscitation
年,卷(期) swyxgcyw_2018,(9) 所属期刊栏目
研究方向 页码范围 235-246
页数 12页 分类号 R73
字数 语种
DOI
五维指标
传播情况
(/次)
(/年)
引文网络
引文网络
二级参考文献  (0)
共引文献  (0)
参考文献  (0)
节点文献
引证文献  (0)
同被引文献  (0)
二级引证文献  (0)
2018(0)
  • 参考文献(0)
  • 二级参考文献(0)
  • 引证文献(0)
  • 二级引证文献(0)
研究主题发展历程
节点文献
Reprocessing
Low-Resource
BAG
VALVE
Mask
Single-Use
Device
Low-and
Middle-Income
Countries
Newborn
Resuscitation
研究起点
研究来源
研究分支
研究去脉
引文网络交叉学科
相关学者/机构
期刊影响力
生物医学工程(英文)
月刊
1937-6871
武汉市江夏区汤逊湖北路38号光谷总部空间
出版文献量(篇)
252
总下载数(次)
1
论文1v1指导